Drinking water in the Savinjska region
In 2024–2026 the state monitoring took 1,038 samples in the Savinjska region, across 141 supply areas; 59 (5.7%) were not compliant. The median estimated hardness is 13.9 °dH.
Municipalities in the Savinjska region
| Municipality | Rating | Samples | Non-compliant | Hardness (°dH) | Nitrate (mg/L) |
|---|---|---|---|---|---|
| Braslovče | compliant | 38 | 0 | 11.9 moderately hard | 5.8 |
| Celje | occasional non-compliance | 108 | 2 | 17.2 hard | 19.6 |
| Dobje | compliant | 5 | 0 | 11 moderately hard | 3 |
| Dobrna | occasional non-compliance | 20 | 1 | 15.6 hard | 3.8 |
| Gornji Grad | occasional non-compliance | 27 | 1 | 9.2 moderately hard | 3.2 |
| Kozje | occasional non-compliance | 16 | 1 | 17.3 hard | 6.65 |
| Laško | mostly compliant | 74 | 1 | 13.8 moderately hard | 4.4 |
| Ljubno | compliant | 20 | 0 | 8 soft | 5.8 |
| Luče | repeated non-compliance | 14 | 2 | 5.9 soft | 3 |
| Mozirje | occasional non-compliance | 24 | 2 | 10.1 moderately hard | 4.4 |
| Nazarje | compliant | 19 | 0 | 9.3 moderately hard | 5.3 |
| Podčetrtek | compliant | 30 | 0 | 15.8 hard | 5.3 |
| Polzela | mostly compliant | 23 | 1 | 13 moderately hard | 6 |
| Prebold | mostly compliant | 20 | 6 | 10.6 moderately hard | 5.3 |
| Rečica ob Savinji | occasional non-compliance | 21 | 4 | 10 moderately hard | 4.4 |
| Rogaška Slatina | occasional non-compliance | 75 | 1 | 16.3 hard | 6.2 |
| Rogatec | occasional non-compliance | 31 | 3 | 15.4 hard | 6.6 |
| Slovenske Konjice | mostly compliant | 62 | 2 | 13.6 moderately hard | 3.65 |
| Solčava | mostly compliant | 18 | 5 | 8.1 soft | 1.45 |
| Šentjur | mostly compliant | 75 | 1 | 18.6 hard | 3.4 |
| Šmarje pri Jelšah | mostly compliant | 74 | 1 | 17.5 hard | 6.2 |
| Šmartno ob Paki | compliant | 5 | 0 | 16.5 hard | – |
| Šoštanj | occasional non-compliance | 65 | 2 | 8 soft | 2.95 |
| Štore | occasional non-compliance | 109 | 6 | 17.3 hard | 19.6 |
| Tabor | occasional non-compliance | 3 | 1 | 7.4 soft | 3.1 |
| Velenje | occasional non-compliance | 68 | 1 | 11.4 moderately hard | 2.8 |
| Vitanje | compliant | 19 | 0 | 15.1 hard | 6 |
| Vojnik | occasional non-compliance | 120 | 7 | 17.2 hard | 11.9 |
| Vransko | occasional non-compliance | 13 | 7 | 9.5 moderately hard | 8.85 |
| Zreče | mostly compliant | 72 | 3 | 14.1 hard | 3.7 |
| Žalec | occasional non-compliance | 77 | 5 | 10 moderately hard | 17 |
Measured values
| Parameter | Highest value | Against the limit |
|---|---|---|
| E. coli | >80 per 100 mL | limit 0 per 100 mL · 1,038 samples · 14× over the limit |
| Enterococci | >80 per 100 mL | limit 0 per 100 mL · 1,038 samples · 15× over the limit |
| Coliform bacteria | >80 per 100 mL | limit 0 per 100 mL · 1,038 samples · 45× over the limit |
| Clostridium perfringens | 6 per 100 mL | limit 0 per 100 mL · 318 samples · 3× over the limit |
| Nitrate | 36 mg/L | limit 50 mg/L · 191 samples |
| Nitrite | 0.01 mg/L | limit 0.5 mg/L · 191 samples |
| Nitrate/50 + nitrite/3 | 0.72 | limit 1 · 191 samples |
| Single pesticide (highest) | 0.025 µg/L (Desetil-atrazin) | limit 0.1 µg/L · 42 samples |
| Pesticides, total | 0.013 µg/L | limit 0.5 µg/L · 12 samples |
| PFAS, total | below 0.03 µg/L | limit 0.5 µg/L · 10 samples |
| PFOA | below 0.0005 µg/L | part of the 20-PFAS sum, limit 0.1 µg/L · 10 samples |
| PFOS | below 0.0005 µg/L | part of the 20-PFAS sum, limit 0.1 µg/L · 10 samples |
| Lead | 12 µg/L | limit 10 µg/L · 78 samples · 1× over the limit |
| Arsenic | 1.4 µg/L | limit 10 µg/L · 113 samples |
| Uranium | 3.3 µg/L | limit 30 µg/L · 61 samples |
| Copper | 0.024 mg/L | limit 2 mg/L · 113 samples |
| Nickel | below 1 µg/L | limit 20 µg/L · 60 samples |
| Cadmium | 0.073 µg/L | limit 5 µg/L · 113 samples |
| Chromium | below 1 µg/L | limit 50 µg/L · 113 samples |
| Antimony | below 1 µg/L | limit 10 µg/L · 113 samples |
| Selenium | 2 µg/L | limit 20 µg/L · 113 samples |
| Boron | 0.067 mg/L | limit 1.5 mg/L · 113 samples |
| Fluoride | 0.19 mg/L | limit 1.5 mg/L · 191 samples |
| Trihalomethanes, total | 7.6 µg/L | limit 100 µg/L · 109 samples |
| Haloacetic acids | 11 µg/L | limit 60 µg/L · 10 samples |
| Bromate | below 3 µg/L | limit 10 µg/L · 21 samples |
| Chlorate | 0.14 mg/L | limit 0.25 mg/L · 68 samples |
| Chlorite | 0.04 mg/L | limit 0.25 mg/L · 68 samples |
| Tetrachloroethene + trichloroethene | below 0.2 µg/L | limit 10 µg/L · 4 samples |
| Bisphenol A | below 0.025 µg/L | limit 2.5 µg/L · 1 sample |
| Free chlorine | 0.9 mg/L | no limit value · 641 samples |
| Manganese | 1.4 µg/L | limit 50 µg/L · 113 samples |
| Iron | 91 µg/L | limit 200 µg/L · 113 samples |
| Aluminium | 75 µg/L | limit 200 µg/L · 139 samples |
| Ammonium | below 0.05 mg/L | limit 0.5 mg/L · 191 samples |
| Chloride | 25 mg/L | limit 250 mg/L · 191 samples |
| Sulphate | 47 mg/L | limit 250 mg/L · 191 samples |
| Sodium | 16 mg/L | limit 200 mg/L · 113 samples |
| pH | 6.5–8.9 | limit 6.5–9.5 · 1,038 samples |
| Electrical conductivity | 813 µS/cm | limit 2,500 µS/cm · 1,038 samples |
Samples by year
How to read the results
- All samples compliant all samples in this period met the Drinking Water Decree.
- Mostly compliant (municipality) non-compliant samples came only from smaller systems that together supply less than a quarter of the users there.
- Occasional non-compliance individual samples were not compliant on indicator parameters (iron, manganese, turbidity, coliform bacteria), which point to a problem in treatment or the network but are not a health limit.
- Faecal bacteria in 1 sample E. coli or enterococci were found in one sample. That is a serious finding, but a single one; check its date and the later samples.
- Repeated or health-relevant non-compliance faecal bacteria (E. coli, enterococci) in two or more samples, or a health-based chemical limit (nitrate, pesticides, lead, arsenic …) exceeded at least once.
The ratings are a Draga Slovenija summary, not an official NIJZ rating.
Other regions
Source: NIJZ and NLZOH, mpv.si; latest sample 31 Aug 2026. Processing: Draga Slovenija.
Frequently asked questions
What is the drinking water like in the Savinjska region?
In 2024–2026 the state monitoring took 1,038 samples in the Savinjska region, across 141 supply areas; 59 (5.7%) were not compliant.
Where is the water hardest in the Savinjska region?
By estimate Šentjur (18.6 °dH), Šmarje pri Jelšah (17.5 °dH), Kozje (17.3 °dH).