Drinking water in the Podravska region
In 2024–2026 the state monitoring took 756 samples in the Podravska region, across 80 supply areas; 64 (8.5%) were not compliant. The median estimated hardness is 15.3 °dH.
Municipalities in the Podravska region
| Municipality | Rating | Samples | Non-compliant | Hardness (°dH) | Nitrate (mg/L) |
|---|---|---|---|---|---|
| Benedikt | compliant | 37 | 0 | 16.5 hard | 12 |
| Cerkvenjak | occasional non-compliance | 17 | 2 | 15.6 hard | 9.3 |
| Cirkulane | repeated non-compliance | 39 | 1 | 16.2 hard | 26.5 |
| Destrnik | occasional non-compliance | 17 | 2 | 15.6 hard | 9.3 |
| Duplek | compliant | 16 | 0 | 18.3 hard | 20 |
| Gorišnica | compliant | 14 | 0 | 15.4 hard | 15 |
| Hajdina | repeated non-compliance | 39 | 1 | 16.2 hard | 26.5 |
| Hoče - Slivnica | occasional non-compliance | 140 | 9 | 17.7 hard | 10.8 |
| Juršinci | compliant | 14 | 0 | 15.4 hard | 15 |
| Lenart | mostly compliant | 47 | 6 | 16.5 hard | 12 |
| Lovrenc na Pohorju | compliant | 9 | 0 | 2.2 soft | 2.45 |
| Majšperk | occasional non-compliance | 15 | 1 | 13.8 moderately hard | 26 |
| Makole | compliant | 8 | 0 | 9.4 moderately hard | 5.3 |
| Maribor | occasional non-compliance | 227 | 9 | 17.3 hard | 13 |
| Miklavž na Dravskem polju | occasional non-compliance | 61 | 1 | 19.4 hard | 25 |
| Oplotnica | repeated non-compliance | 32 | 6 | 6.3 soft | 11.5 |
| Ormož | occasional non-compliance | 22 | 1 | 16 hard | 2.75 |
| Pesnica | compliant | 37 | 0 | 16.5 hard | 12 |
| Poljčane | occasional non-compliance | 9 | 1 | 12.4 moderately hard | 5.05 |
| Ptuj | repeated non-compliance | 54 | 1 | 16 hard | 25.5 |
| Rače - Fram | repeated non-compliance | 17 | 4 | 9.5 moderately hard | 6.6 |
| Ruše | occasional non-compliance | 149 | 12 | 16.2 hard | 13.5 |
| Selnica ob Dravi | mostly compliant | 18 | 2 | 12.5 moderately hard | 13 |
| Slovenska Bistrica | mostly compliant | 138 | 18 | 8.7 moderately hard | 4.9 |
| Središče ob Dravi | occasional non-compliance | 22 | 1 | 16 hard | 2.75 |
| Starše | occasional non-compliance | 15 | 1 | 13.8 moderately hard | 26 |
| Šentilj | compliant | 10 | 0 | 16.5 hard | 9.7 |
| Videm | compliant | 15 | 0 | 14.6 hard | 32 |
| Zavrč | repeated non-compliance | 39 | 1 | 16.2 hard | 26.5 |
| Žetale | compliant | 15 | 0 | 14.6 hard | 32 |
Measured values
| Parameter | Highest value | Against the limit |
|---|---|---|
| E. coli | 4,800 per 100 mL | limit 0 per 100 mL · 756 samples · 14× over the limit |
| Enterococci | >80 per 100 mL | limit 0 per 100 mL · 756 samples · 13× over the limit |
| Coliform bacteria | >8,000 per 100 mL | limit 0 per 100 mL · 756 samples · 54× over the limit |
| Clostridium perfringens | >80 per 100 mL | limit 0 per 100 mL · 290 samples · 6× over the limit |
| Nitrate | 35 mg/L | limit 50 mg/L · 124 samples |
| Nitrite | below 0.01 mg/L | limit 0.5 mg/L · 124 samples |
| Nitrate/50 + nitrite/3 | 0.7 | limit 1 · 124 samples |
| Single pesticide (highest) | 0.12 µg/L (Desetil-atrazin) | limit 0.1 µg/L · 62 samples · 3× over the limit |
| Pesticides, total | 0.3 µg/L | limit 0.5 µg/L · 26 samples |
| PFAS, total | below 0.03 µg/L | limit 0.5 µg/L · 5 samples |
| PFOA | 0.0027 µg/L | part of the 20-PFAS sum, limit 0.1 µg/L · 7 samples |
| PFOS | 0.0018 µg/L | part of the 20-PFAS sum, limit 0.1 µg/L · 7 samples |
| Lead | 1.5 µg/L | limit 10 µg/L · 48 samples |
| Arsenic | 2.7 µg/L | limit 10 µg/L · 79 samples |
| Uranium | 3.6 µg/L | limit 30 µg/L · 39 samples |
| Copper | 0.08 mg/L | limit 2 mg/L · 79 samples |
| Nickel | below 1 µg/L | limit 20 µg/L · 44 samples |
| Cadmium | 0.09 µg/L | limit 5 µg/L · 79 samples |
| Chromium | 3.9 µg/L | limit 50 µg/L · 79 samples |
| Antimony | 0.2 µg/L | limit 10 µg/L · 79 samples |
| Selenium | 3.3 µg/L | limit 20 µg/L · 79 samples |
| Boron | 0.061 mg/L | limit 1.5 mg/L · 79 samples |
| Fluoride | 0.6 mg/L | limit 1.5 mg/L · 124 samples |
| Trihalomethanes, total | 15 µg/L | limit 100 µg/L · 40 samples |
| Haloacetic acids | below 5 µg/L | limit 60 µg/L · 5 samples |
| Bromate | below 2 µg/L | limit 10 µg/L · 6 samples |
| Chlorate | 0.09 mg/L | limit 0.25 mg/L · 19 samples |
| Chlorite | below 0.05 mg/L | limit 0.25 mg/L · 19 samples |
| Benzene | below 0.2 µg/L | limit 1 µg/L · 2 samples |
| PAHs, total | below 0.004 µg/L | limit 0.1 µg/L · 2 samples |
| Benzo(a)pyrene | below 0.004 µg/L | limit 0.01 µg/L · 2 samples |
| Free chlorine | 0.44 mg/L | no limit value · 252 samples |
| Manganese | 8.1 µg/L | limit 50 µg/L · 79 samples |
| Iron | 81 µg/L | limit 200 µg/L · 79 samples |
| Aluminium | 46 µg/L | limit 200 µg/L · 79 samples |
| Ammonium | below 0.05 mg/L | limit 0.5 mg/L · 124 samples |
| Chloride | 51 mg/L | limit 250 mg/L · 124 samples |
| Sulphate | 46 mg/L | limit 250 mg/L · 124 samples |
| Sodium | 26 mg/L | limit 200 mg/L · 79 samples |
| pH | 5.7–8.3 | limit 6.5–9.5 · 755 samples · 6× outside the range |
| Electrical conductivity | 670 µS/cm | limit 2,500 µS/cm · 755 samples |
Samples by year
How to read the results
- All samples compliant all samples in this period met the Drinking Water Decree.
- Mostly compliant (municipality) non-compliant samples came only from smaller systems that together supply less than a quarter of the users there.
- Occasional non-compliance individual samples were not compliant on indicator parameters (iron, manganese, turbidity, coliform bacteria), which point to a problem in treatment or the network but are not a health limit.
- Faecal bacteria in 1 sample E. coli or enterococci were found in one sample. That is a serious finding, but a single one; check its date and the later samples.
- Repeated or health-relevant non-compliance faecal bacteria (E. coli, enterococci) in two or more samples, or a health-based chemical limit (nitrate, pesticides, lead, arsenic …) exceeded at least once.
The ratings are a Draga Slovenija summary, not an official NIJZ rating.
Other regions
Source: NIJZ and NLZOH, mpv.si; latest sample 31 Aug 2026. Processing: Draga Slovenija.
Frequently asked questions
What is the drinking water like in the Podravska region?
In 2024–2026 the state monitoring took 756 samples in the Podravska region, across 80 supply areas; 64 (8.5%) were not compliant.
Where is the water hardest in the Podravska region?
By estimate Miklavž na Dravskem polju (19.4 °dH), Duplek (18.3 °dH), Hoče - Slivnica (17.7 °dH).