Drinking water in the Central Slovenia region
In 2024–2026 the state monitoring took 1,575 samples in the Central Slovenia region, across 144 supply areas; 128 (8.1%) were not compliant. The median estimated hardness is 15 °dH.
Municipalities in the Central Slovenia region
| Municipality | Rating | Samples | Non-compliant | Hardness (°dH) | Nitrate (mg/L) |
|---|---|---|---|---|---|
| Borovnica | occasional non-compliance | 48 | 8 | 17 hard | 4.65 |
| Brezovica | occasional non-compliance | 74 | 6 | 14.2 hard | 5.8 |
| Dobrepolje | occasional non-compliance | 10 | 1 | 16.3 hard | 4.45 |
| Dobrova - Polhov Gradec | occasional non-compliance | 82 | 13 | 11.6 moderately hard | 4.25 |
| Dol pri Ljubljani | occasional non-compliance | 60 | 4 | 15.8 hard | 9.7 |
| Domžale | occasional non-compliance | 110 | 2 | 16.7 hard | 6.7 |
| Grosuplje | mostly compliant | 74 | 2 | 17.6 hard | 4.65 |
| Horjul | occasional non-compliance | 30 | 3 | 15.1 hard | 3.55 |
| Ig | mostly compliant | 36 | 3 | 18.1 hard | 4.9 |
| Ivančna Gorica | occasional non-compliance | 53 | 1 | 16.7 hard | 3.6 |
| Kamnik | occasional non-compliance | 144 | 25 | 7.1 soft | 3.8 |
| Komenda | occasional non-compliance | 35 | 1 | 6.2 soft | 3.45 |
| Ljubljana | occasional non-compliance | 585 | 27 | 14.6 hard | 12 |
| Logatec | mostly compliant | 62 | 3 | 15.1 hard | 4.4 |
| Lukovica | occasional non-compliance | 28 | 5 | 16.4 hard | 6.05 |
| Medvode | occasional non-compliance | 72 | 12 | 15.9 hard | 7.5 |
| Mengeš | occasional non-compliance | 80 | 2 | 17.2 hard | 24 |
| Moravče | compliant | 10 | 0 | 17.5 hard | 4.55 |
| Škofljica | occasional non-compliance | 97 | 4 | 14.7 hard | 12 |
| Šmartno pri Litiji | occasional non-compliance | 66 | 9 | 14.8 hard | 3.5 |
| Trzin | occasional non-compliance | 70 | 1 | 17.5 hard | 27 |
| Velike Lašče | mostly compliant | 33 | 1 | 17.7 hard | 4 |
| Vodice | compliant | 19 | 0 | 9.4 moderately hard | 4.6 |
| Vrhnika | occasional non-compliance | 69 | 7 | 16.9 hard | 4 |
Measured values
| Parameter | Highest value | Against the limit |
|---|---|---|
| E. coli | >80 per 100 mL | limit 0 per 100 mL · 1,575 samples · 20× over the limit |
| Enterococci | 72 per 100 mL | limit 0 per 100 mL · 1,575 samples · 28× over the limit |
| Coliform bacteria | >80 per 100 mL | limit 0 per 100 mL · 1,575 samples · 90× over the limit |
| Clostridium perfringens | 9 per 100 mL | limit 0 per 100 mL · 421 samples · 14× over the limit |
| Nitrate | 31 mg/L | limit 50 mg/L · 273 samples |
| Nitrite | 0.11 mg/L | limit 0.5 mg/L · 267 samples |
| Nitrate/50 + nitrite/3 | 0.62 | limit 1 · 269 samples |
| Single pesticide (highest) | 0.052 µg/L (Desetil-atrazin) | limit 0.1 µg/L · 12 samples |
| Pesticides, total | 0.086 µg/L | limit 0.5 µg/L · 6 samples |
| PFAS, total | below 0.03 µg/L | limit 0.5 µg/L · 17 samples |
| PFOA | 0.0021 µg/L | part of the 20-PFAS sum, limit 0.1 µg/L · 19 samples |
| PFOS | 0.0083 µg/L | part of the 20-PFAS sum, limit 0.1 µg/L · 19 samples |
| Lead | 16 µg/L | limit 10 µg/L · 100 samples · 2× over the limit |
| Arsenic | below 1 µg/L | limit 10 µg/L · 154 samples |
| Uranium | 0.92 µg/L | limit 30 µg/L · 83 samples |
| Copper | 0.068 mg/L | limit 2 mg/L · 154 samples |
| Nickel | 2.7 µg/L | limit 20 µg/L · 83 samples |
| Cadmium | 0.078 µg/L | limit 5 µg/L · 154 samples |
| Chromium | 16 µg/L | limit 50 µg/L · 154 samples |
| Antimony | below 1 µg/L | limit 10 µg/L · 154 samples |
| Selenium | 2.3 µg/L | limit 20 µg/L · 154 samples |
| Boron | 0.048 mg/L | limit 1.5 mg/L · 154 samples |
| Fluoride | 0.19 mg/L | limit 1.5 mg/L · 271 samples |
| Trihalomethanes, total | 19 µg/L | limit 100 µg/L · 86 samples |
| Haloacetic acids | 18 µg/L | limit 60 µg/L · 17 samples |
| Bromate | below 2 µg/L | limit 10 µg/L · 1 sample |
| Chlorate | 0.48 mg/L | limit 0.25 mg/L · 51 samples · 2× over the limit |
| Chlorite | below 0.01 mg/L | limit 0.25 mg/L · 51 samples |
| Tetrachloroethene + trichloroethene | 1.5 µg/L | limit 10 µg/L · 45 samples |
| Bisphenol A | below 0.025 µg/L | limit 2.5 µg/L · 3 samples |
| Free chlorine | 0.38 mg/L | no limit value · 531 samples |
| Manganese | 2.9 µg/L | limit 50 µg/L · 154 samples |
| Iron | 53 µg/L | limit 200 µg/L · 154 samples |
| Aluminium | 58 µg/L | limit 200 µg/L · 158 samples |
| Ammonium | 0.026 mg/L | limit 0.5 mg/L · 273 samples |
| Chloride | 45 mg/L | limit 250 mg/L · 273 samples |
| Sulphate | 180 mg/L | limit 250 mg/L · 273 samples |
| Sodium | 24 mg/L | limit 200 mg/L · 154 samples |
| pH | 6.3–8.3 | limit 6.5–9.5 · 1,575 samples · 2× outside the range |
| Electrical conductivity | 748 µS/cm | limit 2,500 µS/cm · 1,575 samples |
Samples by year
How to read the results
- All samples compliant all samples in this period met the Drinking Water Decree.
- Mostly compliant (municipality) non-compliant samples came only from smaller systems that together supply less than a quarter of the users there.
- Occasional non-compliance individual samples were not compliant on indicator parameters (iron, manganese, turbidity, coliform bacteria), which point to a problem in treatment or the network but are not a health limit.
- Faecal bacteria in 1 sample E. coli or enterococci were found in one sample. That is a serious finding, but a single one; check its date and the later samples.
- Repeated or health-relevant non-compliance faecal bacteria (E. coli, enterococci) in two or more samples, or a health-based chemical limit (nitrate, pesticides, lead, arsenic …) exceeded at least once.
The ratings are a Draga Slovenija summary, not an official NIJZ rating.
Other regions
Source: NIJZ and NLZOH, mpv.si; latest sample 31 Aug 2026. Processing: Draga Slovenija.
Frequently asked questions
What is the drinking water like in the Central Slovenia region?
In 2024–2026 the state monitoring took 1,575 samples in the Central Slovenia region, across 144 supply areas; 128 (8.1%) were not compliant.
Where is the water hardest in the Central Slovenia region?
By estimate Ig (18.1 °dH), Velike Lašče (17.7 °dH), Grosuplje (17.6 °dH).