Draga SlovenijaDraga Slovenija

Drinking water in Vrhnika

Occasional non-compliance

In 2024–2026 the state monitoring took 69 samples of drinking water on the 6 supply areas serving the municipality, of which 7 were not compliant (E. coli or enterococci bacteria in 3 samples). The water is estimated to be hard (≈16.9 °dH).

These are state monitoring results from 2024–2026, not a notice about the water today. Current notices (boil-water, do-not-use) are published by the water-system operator on its website.

Samples 2024–2026696 supply areas
Non-compliant710%
Hardness (estimate)16.9 °dHhard
Nitrate, median4 mg/Llimit 50 mg/L

Water systems in Vrhnika

In 2024–2026 the state monitoring sampled 6 supply areas; the largest, Vrhnika - Borovnica, supplies 20,522 users. The address search shows the nearest sampling points, not necessarily your water system; the system that supplies you is named on your water bill.

Supply areas at a glance
AreaUsersRating
Vrhnika - Borovnica20,522occasional non-compliance
Ligojna574Faecal bacteria in 1 sample
ZAPLANA - ZGORNJA572occasional non-compliance
PODLIPA420Faecal bacteria in 1 sample
SAMIJA97Faecal bacteria in 1 sample
POKOJIŠČE73compliant
Vrhnika - Borovnica: occasional non-complianceVrhnika - Borovnica: occasional non-complianceLigojna: occasional non-complianceZAPLANA - ZGORNJA: occasional non-compliancePODLIPA: occasional non-complianceSAMIJA: occasional non-compliancePOKOJIŠČE: compliantVrhnikaPodlipaPokojiščeDrenov GričVelika LigojnaSmrečjeBistraBevkeBlatna BrezovicaJamnikLogatecHorjulBorovnicaDobrova-Polhov GradecLog-DragomerCerknicaŽiri5 km
  • compliant
  • occasional non-compliance

Sampling points of the state monitoring in recent years, coloured by the result for the area. Click a dot for the area's figures. Place names © OpenStreetMap

Vrhnika - Borovnica

Occasional non-compliance

Operator: Komunalno podjetje Vrhnika · 20,522 users · water system Vrhnika - Borovnica- Log - Dragomer

The area also extends into Borovnica.

Samples 2024–2026
33, 3 non-compliant
Water source
Groundwater, not influenced by surface water
Treatment
Sodium hypochlorite disinfection, UV disinfection
Hardness (estimate)
≈17.1 °dH, hard
Latest sample
10 Jul 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 33 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 33 samples
Nitrate5.8 mg/Llimit 50 mg/L · 5 samples
Single pesticide (highest)0.029 µg/L (Atrazin)limit 0.1 µg/L · 4 samples
Arsenicbelow 1 µg/Llimit 10 µg/L · 4 samples
Manganesebelow 1 µg/Llimit 50 µg/L · 4 samples
Iron12 µg/Llimit 200 µg/L · 4 samples
Non-compliant samples (3)
  • · marked non-compliant; the published data gives no reason
  • · Coliform bacteria 1 per 100 mL limit 0 per 100 mL
  • · Coliform bacteria 2 per 100 mL limit 0 per 100 mL

Ligojna

Faecal bacteria in 1 sample

Operator: Komunalno podjetje Vrhnika · 574 users · water system Ligojna

Samples 2024–2026
10, 1 non-compliant
Water source
Groundwater, not influenced by surface water
Treatment
Sodium hypochlorite disinfection
Hardness (estimate)
≈15.4 °dH, hard
Latest sample
28 Aug 2026
Measured values
E. coli>2 per 100 mLlimit 0 per 100 mL · 10 samples · 1× over the limit
Enterococci0 per 100 mLlimit 0 per 100 mL · 10 samples
Nitrate1.5 mg/Llimit 50 mg/L · 3 samples
Arsenicbelow 1 µg/Llimit 10 µg/L · 2 samples
Manganesebelow 1 µg/Llimit 50 µg/L · 2 samples
Ironbelow 10 µg/Llimit 200 µg/L · 2 samples
Non-compliant samples (1)
  • · E. coli >2 per 100 mL limit 0 per 100 mL, Coliform bacteria >2 per 100 mL limit 0 per 100 mL

ZAPLANA - ZGORNJA

Occasional non-compliance

Operator: Komunalno podjetje Vrhnika · 572 users · water system Zaplana - Zgornja

Samples 2024–2026
10, 1 non-compliant
Water source
Groundwater, not influenced by surface water
Treatment
UV disinfection
Hardness (estimate)
≈15.2 °dH, hard
Latest sample
10 Aug 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 10 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 10 samples
Nitrate4.1 mg/Llimit 50 mg/L · 3 samples
Arsenicbelow 1 µg/Llimit 10 µg/L · 2 samples
Manganesebelow 1 µg/Llimit 50 µg/L · 2 samples
Ironbelow 10 µg/Llimit 200 µg/L · 2 samples
Non-compliant samples (1)
  • · Coliform bacteria 3 per 100 mL limit 0 per 100 mL

PODLIPA

Faecal bacteria in 1 sample

Operator: Bagrček Franc Železnik · 420 users · water system Podlipa

Samples 2024–2026
6, 1 non-compliant
Water source
Influenced by surface water
Treatment
UV disinfection
Hardness (estimate)
≈14.1 °dH, hard
Latest sample
28 Aug 2026
Measured values
E. coli6 per 100 mLlimit 0 per 100 mL · 6 samples · 1× over the limit
Enterococci10 per 100 mLlimit 0 per 100 mL · 6 samples · 1× over the limit
Nitrate3.9 mg/Llimit 50 mg/L · 2 samples
Lead0.22 µg/Llimit 10 µg/L · 3 samples
Non-compliant samples (1)
  • · E. coli 6 per 100 mL limit 0 per 100 mL, Enterococci 10 per 100 mL limit 0 per 100 mL, Coliform bacteria 46 per 100 mL limit 0 per 100 mL

SAMIJA

Faecal bacteria in 1 sample

Operator: Bagrček Franc Železnik · 97 users · water system Samija

Samples 2024–2026
5, 1 non-compliant
Water source
Influenced by surface water
Treatment
Sodium hypochlorite disinfection
Hardness (estimate)
≈12.1 °dH, moderately hard
Latest sample
12 May 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci50 per 100 mLlimit 0 per 100 mL · 5 samples · 1× over the limit
Nitrate4.3 mg/Llimit 50 mg/L · 2 samples
Leadbelow 1 µg/Llimit 10 µg/L · 2 samples
Non-compliant samples (1)
  • · Enterococci 50 per 100 mL limit 0 per 100 mL

POKOJIŠČE

All samples compliant

Operator: Komunalno podjetje Vrhnika · 73 users · water system Pokojišče

Samples 2024–2026
5, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
UV disinfection
Hardness (estimate)
≈13 °dH, moderately hard
Latest sample
1 Apr 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples
Nitrate4.9 mg/Llimit 50 mg/L · 1 sample

Measured values 2024–2026

The highest measured value of each parameter in the samples from the water systems that supply the municipality, and the share of the limit it reaches.

ParameterHighest valueAgainst the limit
E. coli6 per 100 mLlimit 0 per 100 mL · 69 samples · 2× over the limit
Enterococci50 per 100 mLlimit 0 per 100 mL · 69 samples · 2× over the limit
Coliform bacteria46 per 100 mLlimit 0 per 100 mL · 69 samples · 5× over the limit
Clostridium perfringens0 per 100 mLlimit 0 per 100 mL · 11 samples
Nitrate5.8 mg/Llimit 50 mg/L · 16 samples
Nitritebelow 0.007 mg/Llimit 0.5 mg/L · 16 samples
Nitrate/50 + nitrite/30.12limit 1 · 16 samples
Single pesticide (highest)0.029 µg/L (Atrazin)limit 0.1 µg/L · 4 samples
Pesticides, total0.058 µg/Llimit 0.5 µg/L · 2 samples
Lead0.22 µg/Llimit 10 µg/L · 5 samples
Arsenicbelow 1 µg/Llimit 10 µg/L · 8 samples
Uranium0.92 µg/Llimit 30 µg/L · 4 samples
Copper0.015 mg/Llimit 2 mg/L · 8 samples
Nickel1.3 µg/Llimit 20 µg/L · 4 samples
Cadmium0.078 µg/Llimit 5 µg/L · 8 samples
Chromiumbelow 1 µg/Llimit 50 µg/L · 8 samples
Antimonybelow 1 µg/Llimit 10 µg/L · 8 samples
Selenium1.5 µg/Llimit 20 µg/L · 8 samples
Boronbelow 0.01 mg/Llimit 1.5 mg/L · 8 samples
Fluoride0.19 mg/Llimit 1.5 mg/L · 16 samples
Trihalomethanes, total1.1 µg/Llimit 100 µg/L · 2 samples
Chloratebelow 0.01 mg/Llimit 0.25 mg/L · 2 samples
Chloritebelow 0.01 mg/Llimit 0.25 mg/L · 2 samples
Tetrachloroethene + trichloroethenebelow 0.2 µg/Llimit 10 µg/L · 2 samples
Free chlorine0.24 mg/Lno limit value · 16 samples
Manganesebelow 1 µg/Llimit 50 µg/L · 8 samples
Iron12 µg/Llimit 200 µg/L · 8 samples
Aluminium15 µg/Llimit 200 µg/L · 8 samples
Ammoniumbelow 0.013 mg/Llimit 0.5 mg/L · 16 samples
Chloride9.9 mg/Llimit 250 mg/L · 16 samples
Sulphate180 mg/Llimit 250 mg/L · 16 samples
Sodium7.6 mg/Llimit 200 mg/L · 8 samples
pH7–7.9limit 6.5–9.5 · 69 samples
Electrical conductivity748 µS/cmlimit 2,500 µS/cm · 69 samples

Non-compliant samples

What the laboratory found in the samples that were not compliant:

Samples by year

016312016: 29 samples, 1 non-compliant’162017: 28 samples, 3 non-compliant’172018: 31 samples, 2 non-compliant’182019: 31 samples, 4 non-compliant’192020: 27 samples, 5 non-compliant’202021: 27 samples, 3 non-compliant’212022: 27 samples, 4 non-compliant’222023: 27 samples, 3 non-compliant’232024: 27 samples, 2 non-compliant’242025: 27 samples, 4 non-compliant’252026: 15 samples, 1 non-compliant’26
compliant non-compliant · Drinking-water samples in Vrhnika since 2016

What you can do

How to read the results

The ratings are a Draga Slovenija summary, not an official NIJZ rating.

More about water and property in Vrhnika

Estimate a property’s valueProperty prices in Vrhnika

Drinking water in neighbouring municipalities in the Central Slovenia region: Ljubljana, Brezovica, Škofljica, Ivančna Gorica, Borovnica, Dol pri Ljubljani, Vodice, Velike Lašče, Ig, Domžale, Mengeš, Trzin, Moravče, Lukovica, Medvode, Kamnik, Komenda, Dobrova - Polhov Gradec, Horjul, Dobrepolje, Grosuplje, Šmartno pri Litiji, Logatec.

Explanations of the parameters:

Follow the results for your address

When the state monitoring publishes a non-compliant result for the area by your address, we e-mail you (results come out about once a month). One address is free. This is not an urgent boil-water alert; the operator announces those.

Find your address and turn on following →

Monthly e-mail roundup: drinking water and the property market

Once a month: new drinking-water results and how the property market moved, in one e-mail. This is our existing monthly newsletter; we do not send a report for a single municipality. Unsubscribe with one click in every e-mail.

Email address only. Privacy statement.

Source: NIJZ and NLZOH, mpv.si; latest sample 31 Aug 2026. Processing: Draga Slovenija.

Frequently asked questions

Is the water in Vrhnika safe to drink?

These are past results, not a verdict on the water today; the operator announces current restrictions (boil-water notices). In 2024–2026 the state monitoring took 69 samples of drinking water on the 6 supply areas serving the municipality, of which 7 were not compliant (E. coli or enterococci bacteria in 3 samples). Details by water system are above.

How hard is the water in Vrhnika?

Estimated from electrical conductivity at 16.9 °dH, which is hard water. The operator publishes the exact value for its network.

Who operates the water supply in Vrhnika?

KOMUNALNO PODJETJE VRHNIKA, Bagrček Franc Železnik. The largest supply area is Vrhnika - Borovnica.

Where are the official drinking-water test results?

The state monitoring publishes its results at mpv.si, and the operator publishes an annual report on internal control on its website. This page summarises the state monitoring since 2016.

AI chat

Ask the data, in plain language

The AI chat finds the answer in the official register and shows it with a table you can download and a link into the map. Free; it only needs an account.

For example: Which municipalities issued the most building permits last year?

Open the AI chat

AI chat