Draga SlovenijaDraga Slovenija

Drinking water: Radlje water system

Occasional non-compliance

The Radlje water system (operator JKP RADLJE) supplies 7,120 users in the municipalities of Radlje ob Dravi, Podvelka. In 2024–2026 the state monitoring took 43 samples, of which 2 were not compliant.

These are state monitoring results from 2024–2026, not a notice about the water today. Current notices (boil-water, do-not-use) are published by the water-system operator on its website.

Samples 2024–2026436 supply areas
Non-compliant24.7%
Hardness (estimate)15.9 °dHhard
Users7,120JKP RADLJE

Supply areas

RADLJE OB DRAVI

All samples compliant

Operator: JKP Radlje · 5,500 users · water system Radlje

Samples 2024–2026
15, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
No treatment
Hardness (estimate)
≈16.5 °dH, hard
Latest sample
15 May 2026
E. coli0 per 100 mLlimit 0 per 100 mL · 15 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 15 samples
Nitrate22 mg/Llimit 50 mg/L · 4 samples
Single pesticide (highest)0.053 µg/L (Metolaklor ESA)limit 0.1 µg/L · 5 samples
PFAS, totalbelow 0.03 µg/Llimit 0.5 µg/L · 1 sample
Arsenicbelow 1 µg/Llimit 10 µg/L · 5 samples
Manganesebelow 1 µg/Llimit 50 µg/L · 5 samples
Ironbelow 10 µg/Llimit 200 µg/L · 5 samples

VUHRED

All samples compliant

Operator: JKP Radlje · 530 users · water system Radlje

Samples 2024–2026
9, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
Sodium hypochlorite disinfection
Hardness (estimate)
≈9.3 °dH, moderately hard
Latest sample
11 Mar 2026
E. coli0 per 100 mLlimit 0 per 100 mL · 9 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 9 samples
Nitrate3 mg/Llimit 50 mg/L · 2 samples
Arsenicbelow 1 µg/Llimit 10 µg/L · 2 samples
Manganesebelow 1 µg/Llimit 50 µg/L · 2 samples
Ironbelow 10 µg/Llimit 200 µg/L · 2 samples

BREZNO

Occasional non-compliance

Operator: JKP Radlje · 360 users · water system Radlje

Samples 2024–2026
5, 1 non-compliant
Water source
Groundwater, not influenced by surface water
Treatment
No treatment
Hardness (estimate)
≈16.6 °dH, hard
Latest sample
11 Mar 2026
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples
Nitrate15 mg/Llimit 50 mg/L · 1 sample
Non-compliant samples (1)
  • · marked non-compliant; the published data gives no reason

PODVELKA - RADLJE

Occasional non-compliance

Operator: JKP Radlje · 320 users · water system Radlje

Samples 2024–2026
5, 1 non-compliant
Water source
Groundwater, not influenced by surface water
Treatment
No treatment
Hardness (estimate)
≈16.5 °dH, hard
Latest sample
20 Apr 2026
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples
Nitrate16 mg/Llimit 50 mg/L · 1 sample
Non-compliant samples (1)
  • · marked non-compliant; the published data gives no reason

VAS - KOZJI VRH

All samples compliant

Operator: JKP Radlje · 250 users · water system Radlje

Samples 2024–2026
5, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
No treatment
Hardness (estimate)
≈15.5 °dH, hard
Latest sample
20 Apr 2026
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples
Nitrate17 mg/Llimit 50 mg/L · 1 sample

ZGORNJA VIŽINGA

All samples compliant

Operator: JKP Radlje · 160 users · water system Radlje

Samples 2024–2026
4, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
Sodium hypochlorite disinfection
Hardness (estimate)
≈16.5 °dH, hard
Latest sample
11 Mar 2026
E. coli0 per 100 mLlimit 0 per 100 mL · 4 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 4 samples
Nitrate15 mg/Llimit 50 mg/L · 1 sample

Measured values 2024–2026

ParameterHighest valueAgainst the limit
E. coli0 per 100 mLlimit 0 per 100 mL · 43 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 43 samples
Coliform bacteria0 per 100 mLlimit 0 per 100 mL · 43 samples
Nitrate22 mg/Llimit 50 mg/L · 10 samples
Nitritebelow 0.007 mg/Llimit 0.5 mg/L · 10 samples
Nitrate/50 + nitrite/30.44limit 1 · 10 samples
Single pesticide (highest)0.053 µg/L (Metolaklor ESA)limit 0.1 µg/L · 5 samples
Pesticides, total0.11 µg/Llimit 0.5 µg/L · 3 samples
PFAS, totalbelow 0.03 µg/Llimit 0.5 µg/L · 1 sample
PFOAbelow 0.0005 µg/Lpart of the 20-PFAS sum, limit 0.1 µg/L · 1 sample
PFOSbelow 0.0005 µg/Lpart of the 20-PFAS sum, limit 0.1 µg/L · 1 sample
Arsenicbelow 1 µg/Llimit 10 µg/L · 7 samples
Uranium0.83 µg/Llimit 30 µg/L · 4 samples
Copper0.0047 mg/Llimit 2 mg/L · 7 samples
Nickel3 µg/Llimit 20 µg/L · 4 samples
Cadmiumbelow 0.1 µg/Llimit 5 µg/L · 7 samples
Chromiumbelow 1 µg/Llimit 50 µg/L · 7 samples
Antimony0.43 µg/Llimit 10 µg/L · 7 samples
Seleniumbelow 1 µg/Llimit 20 µg/L · 7 samples
Boron0.02 mg/Llimit 1.5 mg/L · 7 samples
Fluoride0.11 mg/Llimit 1.5 mg/L · 10 samples
Haloacetic acidsbelow 5 µg/Llimit 60 µg/L · 1 sample
Manganesebelow 1 µg/Llimit 50 µg/L · 7 samples
Ironbelow 10 µg/Llimit 200 µg/L · 7 samples
Aluminiumbelow 10 µg/Llimit 200 µg/L · 7 samples
Ammoniumbelow 0.013 mg/Llimit 0.5 mg/L · 10 samples
Chloride33 mg/Llimit 250 mg/L · 10 samples
Sulphate20 mg/Llimit 250 mg/L · 10 samples
Sodium19 mg/Llimit 200 mg/L · 7 samples
pH7.3–8.2limit 6.5–9.5 · 43 samples
Electrical conductivity536 µS/cmlimit 2,500 µS/cm · 43 samples

Non-compliant samples

Samples by year

011222016: 22 samples, 11 non-compliant’162017: 22 samples, 5 non-compliant’172018: 22 samples, 9 non-compliant’182019: 22 samples, 3 non-compliant’192020: 19 samples, 3 non-compliant’202021: 19 samples, 3 non-compliant’212022: 18 samples, all compliant’222023: 19 samples, all compliant’232024: 18 samples, 2 non-compliant’242025: 18 samples, all compliant’252026: 7 samples, all compliant’26
compliant non-compliant · Samples from the Radlje water system

Municipalities

Drinking water in Radlje ob Dravi · Drinking water in Podvelka

What you can do

How to read the results

The ratings are a Draga Slovenija summary, not an official NIJZ rating.

Follow the results for your address

When the state monitoring publishes a non-compliant result for the area by your address, we e-mail you (results come out about once a month). One address is free. This is not an urgent boil-water alert; the operator announces those.

Find your address and turn on following →

Source: NIJZ and NLZOH, mpv.si; latest sample 31 Aug 2026. Processing: Draga Slovenija.

Frequently asked questions

Is the water from the Radlje water system safe to drink?

The Radlje water system (operator JKP RADLJE) supplies 7,120 users in the municipalities of Radlje ob Dravi, Podvelka. In 2024–2026 the state monitoring took 43 samples, of which 2 were not compliant. The operator announces current restrictions on use.

How hard is the water from the Radlje water system?

Estimated from electrical conductivity at 15.9 °dH, which is hard water.

AI chat

Ask the data, in plain language

The AI chat finds the answer in the official register and shows it with a table you can download and a link into the map. Free; it only needs an account.

For example: Which municipalities issued the most building permits last year?

Open the AI chat

AI chat