JKP Radlje supplies drinking water to 13,335 users in the municipalities of Radlje ob Dravi, Muta, Vuzenica, Podvelka, Ribnica na Pohorju, Dravograd. In 2024–2026 the state monitoring sampled 12 water systems of this operator and took 106 samples, of which 7 were not compliant. Water hardness differs between systems, 2–21.4 °dH; most customers get moderately hard water (≈13.5 °dH).

These are state monitoring results from 2024–2026, not a notice about the water today. Current notices (boil-water, do-not-use) are published by the water-system operator on its website.

Samples 2024–202610612 water systems
Non-compliant76.6%
Hardness2–21.4 °dHmoderately hard
Users13,3356 municipalities

Notices from JKP Radlje

Boil-water notices, bans on use and supply interruptions are published by JKP Radlje on its website and in local media. This page shows state monitoring results, not current notices. What a boil-water notice means is explained on Boiling water.

Water systems run by JKP Radlje

Water systemMunicipalitiesUsersHardness (°dH)Assessment
RadljeRadlje ob Dravi, Podvelka7,120≈15.9Occasional non-compliance
Muta - GortinaMuta2,665≈5Occasional non-compliance
VuzenicaVuzenica2,000≈21.4compliant
Ribnica na PohorjuRibnica na Pohorju400≈2compliant
OžbaltPodvelka250≈6.8compliant
JosipdolRibnica na Pohorju190≈2.2compliant
RemšnikRadlje ob Dravi180≈16.1compliant
Sp. Gorče -TribejDravograd140≈11.8compliant
PodvelkaPodvelka120≈16.8Occasional non-compliance
LehenPodvelka100≈2.2Occasional non-compliance
DravčeVuzenica100≈3.9Occasional non-compliance
KaplaPodvelka70≈5compliant

Measured values 2024–2026

ParameterHighest valueAgainst the limit
E. coli0 per 100 mLlimit 0 per 100 mL · 106 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 106 samples
Coliform bacteria74 per 100 mLlimit 0 per 100 mL · 106 samples · 3× over the limit
Clostridium perfringens0 per 100 mLlimit 0 per 100 mL · 51 samples
Nitrate29 mg/Llimit 50 mg/L · 18 samples
Nitritebelow 0.007 mg/Llimit 0.5 mg/L · 18 samples
Nitrate/50 + nitrite/30.58limit 1 · 18 samples
Single pesticide (highest)0.053 µg/L (Metolaklor ESA)limit 0.1 µg/L · 5 samples
Pesticides, total0.11 µg/Llimit 0.5 µg/L · 3 samples
PFAS, totalbelow 0.03 µg/Llimit 0.5 µg/L · 1 sample
PFOAbelow 0.0005 µg/Lpart of the 20-PFAS sum, limit 0.1 µg/L · 1 sample
PFOSbelow 0.0005 µg/Lpart of the 20-PFAS sum, limit 0.1 µg/L · 1 sample
Leadbelow 1 µg/Llimit 10 µg/L · 1 sample
Arsenicbelow 1 µg/Llimit 10 µg/L · 11 samples
Uranium3.4 µg/Llimit 30 µg/L · 6 samples
Copper0.0047 mg/Llimit 2 mg/L · 11 samples
Nickel3 µg/Llimit 20 µg/L · 6 samples
Cadmiumbelow 0.1 µg/Llimit 5 µg/L · 11 samples
Chromiumbelow 1 µg/Llimit 50 µg/L · 11 samples
Antimony0.43 µg/Llimit 10 µg/L · 11 samples
Seleniumbelow 1 µg/Llimit 20 µg/L · 11 samples
Boron0.028 mg/Llimit 1.5 mg/L · 11 samples
Fluoride0.13 mg/Llimit 1.5 mg/L · 18 samples
Trihalomethanes, total2.4 µg/Llimit 100 µg/L · 4 samples
Haloacetic acidsbelow 5 µg/Llimit 60 µg/L · 1 sample
Chlorate0.13 mg/Llimit 0.25 mg/L · 7 samples
Chloritebelow 0.01 mg/Llimit 0.25 mg/L · 7 samples
Free chlorine0.28 mg/Lno limit value · 39 samples
Manganese1.5 µg/Llimit 50 µg/L · 11 samples
Ironbelow 10 µg/Llimit 200 µg/L · 11 samples
Aluminiumbelow 10 µg/Llimit 200 µg/L · 11 samples
Ammoniumbelow 0.013 mg/Llimit 0.5 mg/L · 18 samples
Chloride33 mg/Llimit 250 mg/L · 18 samples
Sulphate47 mg/Llimit 250 mg/L · 18 samples
Sodium19 mg/Llimit 200 mg/L · 11 samples
pH6.6–8.8limit 6.5–9.5 · 106 samples
Electrical conductivity646 µS/cmlimit 2,500 µS/cm · 106 samples

Non-compliant samples

Samples by year

028552016: 53 samples, 22 non-compliant’162017: 53 samples, 14 non-compliant’172018: 53 samples, 15 non-compliant’182019: 55 samples, 8 non-compliant’192020: 49 samples, 6 non-compliant’202021: 49 samples, 8 non-compliant’212022: 48 samples, 2 non-compliant’222023: 47 samples, 4 non-compliant’232024: 44 samples, 6 non-compliant’242025: 46 samples, 1 non-compliant’252026: 16 samples, all compliant’26
compliant non-compliant · Samples from JKP Radlje systems

Municipalities

Drinking water in Radlje ob Dravi · Drinking water in Muta · Drinking water in Vuzenica · Drinking water in Podvelka · Drinking water in Ribnica na Pohorju · Drinking water in Dravograd

What you can do

How to read the results

The ratings are a Draga Slovenija summary, not an official NIJZ rating.

Source: NIJZ and NLZOH, mpv.si; latest sample 31 Aug 2026. Processing: Draga Slovenija.

Frequently asked questions

Is the water from JKP Radlje safe to drink?

JKP Radlje supplies drinking water to 13,335 users in the municipalities of Radlje ob Dravi, Muta, Vuzenica, Podvelka, Ribnica na Pohorju, Dravograd. In 2024–2026 the state monitoring sampled 12 water systems of this operator and took 106 samples, of which 7 were not compliant. The operator announces current restrictions on use.

How hard is the water from JKP Radlje?

Water hardness differs between systems, 2–21.4 °dH; most customers get moderately hard water (≈13.5 °dH).

Where does JKP Radlje publish boil-water notices?

On its website and in local media. A boil-water notice applies until the operator lifts it.

AI chat

Ask the data, in plain language

The AI chat finds the answer in the official register and shows it with a table you can download and a link into the map. Free; it only needs an account.

For example: Which municipalities issued the most building permits last year?

Open the AI chat

AI chat