Draga SlovenijaDraga Slovenija

Drinking water in Radlje ob Dravi

All samples compliant

In 2024–2026 the state monitoring took 38 samples of drinking water on the 5 supply areas serving the municipality, and all were compliant. The water is estimated to be hard (≈15.9 °dH).

These are state monitoring results from 2024–2026, not a notice about the water today. Current notices (boil-water, do-not-use) are published by the water-system operator on its website.

Samples 2024–2026385 supply areas
Non-compliant00%
Hardness (estimate)15.9 °dHhard
Nitrate, median16 mg/Llimit 50 mg/L

Water systems in Radlje ob Dravi

In 2024–2026 the state monitoring sampled 5 supply areas; the largest, RADLJE OB DRAVI, supplies 5,500 users. The address search shows the nearest sampling points, not necessarily your water system; the system that supplies you is named on your water bill.

Supply areas at a glance
AreaUsersRating
RADLJE OB DRAVI5,500compliant
VUHRED530compliant
VAS - KOZJI VRH250compliant
REMŠNIK180compliant
ZGORNJA VIŽINGA160compliant
RADLJE OB DRAVI: compliantRADLJE OB DRAVI: compliantRADLJE OB DRAVI: compliantRADLJE OB DRAVI: compliantVUHRED: compliantVAS - KOZJI VRH: compliantVAS - KOZJI VRH: compliantREMŠNIK: compliantZGORNJA VIŽINGA: compliantZGORNJA VIŽINGA: compliantRadlje ob DraviVuhredRemšnikZgornja VižingaBrezni VrhDobravaPodvelkaVuzenicaRibnica na PohorjuMutaLovrenc na Pohorju5 km
  • compliant

Sampling points of the state monitoring in recent years, coloured by the result for the area. Click a dot for the area's figures. Place names © OpenStreetMap

RADLJE OB DRAVI

All samples compliant

Operator: JKP Radlje · 5,500 users · water system Radlje

Samples 2024–2026
15, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
No treatment
Hardness (estimate)
≈16.5 °dH, hard
Latest sample
15 May 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 15 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 15 samples
Nitrate22 mg/Llimit 50 mg/L · 4 samples
Single pesticide (highest)0.053 µg/L (Metolaklor ESA)limit 0.1 µg/L · 5 samples
PFAS, totalbelow 0.03 µg/Llimit 0.5 µg/L · 1 sample
Arsenicbelow 1 µg/Llimit 10 µg/L · 5 samples
Manganesebelow 1 µg/Llimit 50 µg/L · 5 samples
Ironbelow 10 µg/Llimit 200 µg/L · 5 samples

VUHRED

All samples compliant

Operator: JKP Radlje · 530 users · water system Radlje

Samples 2024–2026
9, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
Sodium hypochlorite disinfection
Hardness (estimate)
≈9.3 °dH, moderately hard
Latest sample
11 Mar 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 9 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 9 samples
Nitrate3 mg/Llimit 50 mg/L · 2 samples
Arsenicbelow 1 µg/Llimit 10 µg/L · 2 samples
Manganesebelow 1 µg/Llimit 50 µg/L · 2 samples
Ironbelow 10 µg/Llimit 200 µg/L · 2 samples

VAS - KOZJI VRH

All samples compliant

Operator: JKP Radlje · 250 users · water system Radlje

Samples 2024–2026
5, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
No treatment
Hardness (estimate)
≈15.5 °dH, hard
Latest sample
20 Apr 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples
Nitrate17 mg/Llimit 50 mg/L · 1 sample

REMŠNIK

All samples compliant

Operator: JKP Radlje · 180 users · water system Remšnik

Samples 2024–2026
5, all compliant
Water source
Influenced by surface water
Treatment
Regular disinfection, sodium hypochlorite disinfection
Hardness (estimate)
≈16.1 °dH, hard
Latest sample
11 Mar 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples

ZGORNJA VIŽINGA

All samples compliant

Operator: JKP Radlje · 160 users · water system Radlje

Samples 2024–2026
4, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
Sodium hypochlorite disinfection
Hardness (estimate)
≈16.5 °dH, hard
Latest sample
11 Mar 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 4 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 4 samples
Nitrate15 mg/Llimit 50 mg/L · 1 sample

Measured values 2024–2026

The highest measured value of each parameter in the samples from the water systems that supply the municipality, and the share of the limit it reaches.

ParameterHighest valueAgainst the limit
E. coli0 per 100 mLlimit 0 per 100 mL · 38 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 38 samples
Coliform bacteria0 per 100 mLlimit 0 per 100 mL · 38 samples
Clostridium perfringens0 per 100 mLlimit 0 per 100 mL · 5 samples
Nitrate22 mg/Llimit 50 mg/L · 8 samples
Nitritebelow 0.007 mg/Llimit 0.5 mg/L · 8 samples
Nitrate/50 + nitrite/30.44limit 1 · 8 samples
Single pesticide (highest)0.053 µg/L (Metolaklor ESA)limit 0.1 µg/L · 5 samples
Pesticides, total0.11 µg/Llimit 0.5 µg/L · 3 samples
PFAS, totalbelow 0.03 µg/Llimit 0.5 µg/L · 1 sample
PFOAbelow 0.0005 µg/Lpart of the 20-PFAS sum, limit 0.1 µg/L · 1 sample
PFOSbelow 0.0005 µg/Lpart of the 20-PFAS sum, limit 0.1 µg/L · 1 sample
Arsenicbelow 1 µg/Llimit 10 µg/L · 7 samples
Uranium0.83 µg/Llimit 30 µg/L · 4 samples
Copper0.0047 mg/Llimit 2 mg/L · 7 samples
Nickel3 µg/Llimit 20 µg/L · 4 samples
Cadmiumbelow 0.1 µg/Llimit 5 µg/L · 7 samples
Chromiumbelow 1 µg/Llimit 50 µg/L · 7 samples
Antimony0.43 µg/Llimit 10 µg/L · 7 samples
Seleniumbelow 1 µg/Llimit 20 µg/L · 7 samples
Boron0.02 mg/Llimit 1.5 mg/L · 7 samples
Fluoride0.11 mg/Llimit 1.5 mg/L · 8 samples
Haloacetic acidsbelow 5 µg/Llimit 60 µg/L · 1 sample
Chloratebelow 0.01 mg/Llimit 0.25 mg/L · 1 sample
Chloritebelow 0.01 mg/Llimit 0.25 mg/L · 1 sample
Free chlorine0.12 mg/Lno limit value · 4 samples
Manganesebelow 1 µg/Llimit 50 µg/L · 7 samples
Ironbelow 10 µg/Llimit 200 µg/L · 7 samples
Aluminiumbelow 10 µg/Llimit 200 µg/L · 7 samples
Ammoniumbelow 0.013 mg/Llimit 0.5 mg/L · 8 samples
Chloride33 mg/Llimit 250 mg/L · 8 samples
Sulphate20 mg/Llimit 250 mg/L · 8 samples
Sodium19 mg/Llimit 200 mg/L · 7 samples
pH7.4–8.2limit 6.5–9.5 · 38 samples
Electrical conductivity534 µS/cmlimit 2,500 µS/cm · 38 samples

Samples by year

010202016: 20 samples, 9 non-compliant’162017: 20 samples, 4 non-compliant’172018: 20 samples, 8 non-compliant’182019: 20 samples, 2 non-compliant’192020: 17 samples, 2 non-compliant’202021: 17 samples, 3 non-compliant’212022: 16 samples, all compliant’222023: 17 samples, all compliant’232024: 16 samples, all compliant’242025: 16 samples, all compliant’252026: 6 samples, all compliant’26
compliant non-compliant · Drinking-water samples in Radlje ob Dravi since 2016

What you can do

How to read the results

The ratings are a Draga Slovenija summary, not an official NIJZ rating.

More about water and property in Radlje ob Dravi

Estimate a property’s valueProperty prices in Radlje ob Dravi

Drinking water in neighbouring municipalities in the Koroška region: Dravograd, Mežica, Prevalje, Ravne na Koroškem, Muta, Ribnica na Pohorju, Črna na Koroškem, Podvelka, Slovenj Gradec, Mislinja, Vuzenica.

Explanations of the parameters:

Follow the results for your address

When the state monitoring publishes a non-compliant result for the area by your address, we e-mail you (results come out about once a month). One address is free. This is not an urgent boil-water alert; the operator announces those.

Find your address and turn on following →

Monthly e-mail roundup: drinking water and the property market

Once a month: new drinking-water results and how the property market moved, in one e-mail. This is our existing monthly newsletter; we do not send a report for a single municipality. Unsubscribe with one click in every e-mail.

Email address only. Privacy statement.

Source: NIJZ and NLZOH, mpv.si; latest sample 31 Aug 2026. Processing: Draga Slovenija.

Frequently asked questions

Is the water in Radlje ob Dravi safe to drink?

These are past results, not a verdict on the water today; the operator announces current restrictions (boil-water notices). In 2024–2026 the state monitoring took 38 samples of drinking water on the 5 supply areas serving the municipality, and all were compliant. The results show no problems.

How hard is the water in Radlje ob Dravi?

Estimated from electrical conductivity at 15.9 °dH, which is hard water. The operator publishes the exact value for its network.

Who operates the water supply in Radlje ob Dravi?

JKP RADLJE. The largest supply area is RADLJE OB DRAVI.

Where are the official drinking-water test results?

The state monitoring publishes its results at mpv.si, and the operator publishes an annual report on internal control on its website. This page summarises the state monitoring since 2016.

AI chat

Ask the data, in plain language

The AI chat finds the answer in the official register and shows it with a table you can download and a link into the map. Free; it only needs an account.

For example: Which municipalities issued the most building permits last year?

Open the AI chat

AI chat