Draga SlovenijaDraga Slovenija

Drinking water in Sodražica

Mostly compliant

In 2024–2026 the state monitoring took 25 samples of drinking water on the 5 supply areas serving the municipality, of which 3 were not compliant. The non-compliant samples came from smaller systems; most residents get water from systems without any. By the operators’ figures and our estimate the water is moderately hard (≈12.8 °dH).

These are state monitoring results from 2024–2026, not a notice about the water today. Current notices (boil-water, do-not-use) are published by the water-system operator on its website.

Samples 2024–2026255 supply areas
Non-compliant312%
Hardness (operator and estimate)12.8 °dHmoderately hard
Nitrate, median3.1 mg/Llimit 50 mg/L

Water systems in Sodražica

In 2024–2026 the state monitoring sampled 5 supply areas; the largest, SODRAŽICA, supplies 2,414 users. The address search shows the nearest sampling points, not necessarily your water system; the system that supplies you is named on your water bill.

Supply areas at a glance
AreaUsersRating
SODRAŽICA2,414compliant
ŽIMARICE288occasional non-compliance
STUDENČEVKA - SUŠJE208occasional non-compliance
GORA141compliant
PLANINSKI DOM NA TRAVNI GORI1occasional non-compliance
SODRAŽICA: compliantŽIMARICE: occasional non-complianceGORA: compliantSodražicaŽimariceZamostecZapotokKržetiKračaliPetrinciJanežiLoški PotokVelike LaščeLoška dolina5 km
  • compliant
  • occasional non-compliance

Sampling points of the state monitoring in recent years, coloured by the result for the area. Click a dot for the area's figures. Place names © OpenStreetMap

SODRAŽICA

All samples compliant

Operator: Hydrovod · 2,414 users · water system Kočevje - Ribnica - Sodražica

Samples 2024–2026
10, all compliant
Water source
Influenced by surface water
Treatment
Filters, chlorine gas disinfection
Hardness (operator)
12.3 °dH, moderately hard source 2025
Latest sample
9 Jun 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 10 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 10 samples
Nitrate4.45 mg/Llimit 50 mg/L · 2 samples
Arsenic0.11 µg/Llimit 10 µg/L · 2 samples
Manganesebelow 0.1 µg/Llimit 50 µg/L · 2 samples
Ironbelow 40 µg/Llimit 200 µg/L · 2 samples

ŽIMARICE

Occasional non-compliance

Operator: Hydrovod · 288 users · water system Žimarice

Samples 2024–2026
4, 1 non-compliant
Water source
Groundwater, not influenced by surface water
Treatment
No treatment
Hardness (estimate)
≈13.6 °dH, moderately hard
Latest sample
21 Oct 2025
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 4 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 4 samples
Non-compliant samples (1)
  • · marked non-compliant; the published data gives no reason

STUDENČEVKA - SUŠJE

Occasional non-compliance

Operator: Studenčevka Sušje · 208 users · water system Studenčevka - Sušje

The area also extends into Ribnica.

Samples 2024–2026
5, 1 non-compliant
Water source
Influenced by surface water
Treatment
Sodium hypochlorite disinfection
Hardness (estimate)
≈13.2 °dH, moderately hard
Latest sample
17 Mar 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples
Nitrate2.75 mg/Llimit 50 mg/L · 1 sample
Lead0.34 µg/Llimit 10 µg/L · 2 samples
Non-compliant samples (1)
  • · Coliform bacteria 6 per 100 mL limit 0 per 100 mL

GORA

All samples compliant

Operator: Hydrovod · 141 users · water system Gora

Samples 2024–2026
5, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
UV disinfection
Hardness (operator)
20.1 °dH, hard source 2025
Latest sample
8 Apr 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples
Nitrate1.2 mg/Llimit 50 mg/L · 1 sample

PLANINSKI DOM NA TRAVNI GORI

Occasional non-compliance

Operator: DOM NA TRAVNI GORI STORITVE IN TRGOVINA D. O. O. · 1 user · water system VS Planinski Dom na Travni Gori

Samples 2024–2026
1, 1 non-compliant
Water source
Influenced by surface water
Treatment
UV disinfection
Hardness (estimate)
≈11.7 °dH, moderately hard
Latest sample
29 Apr 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 1 sample
Enterococci0 per 100 mLlimit 0 per 100 mL · 1 sample
Nitrate3.1 mg/Llimit 50 mg/L · 1 sample
Non-compliant samples (1)
  • · marked non-compliant; the published data gives no reason

Measured values 2024–2026

The highest measured value of each parameter in the samples from the water systems that supply the municipality, and the share of the limit it reaches.

ParameterHighest valueAgainst the limit
E. coli0 per 100 mLlimit 0 per 100 mL · 25 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 25 samples
Coliform bacteria6 per 100 mLlimit 0 per 100 mL · 25 samples · 1× over the limit
Clostridium perfringens0 per 100 mLlimit 0 per 100 mL · 16 samples
Nitrate4.45 mg/Llimit 50 mg/L · 5 samples
Nitrite0.0062 mg/Llimit 0.5 mg/L · 5 samples
Nitrate/50 + nitrite/30.089limit 1 · 5 samples
Lead0.34 µg/Llimit 10 µg/L · 2 samples
Arsenic0.11 µg/Llimit 10 µg/L · 2 samples
Uranium0.63 µg/Llimit 30 µg/L · 1 sample
Copper0.0027 mg/Llimit 2 mg/L · 2 samples
Nickel0.13 µg/Llimit 20 µg/L · 1 sample
Cadmiumbelow 0.02 µg/Llimit 5 µg/L · 2 samples
Chromiumbelow 0.4 µg/Llimit 50 µg/L · 2 samples
Antimonybelow 0.05 µg/Llimit 10 µg/L · 2 samples
Seleniumbelow 0.1 µg/Llimit 20 µg/L · 2 samples
Boron0.0032 mg/Llimit 1.5 mg/L · 2 samples
Fluoride0.061 mg/Llimit 1.5 mg/L · 5 samples
Trihalomethanes, total9.6 µg/Llimit 100 µg/L · 2 samples
Chloratebelow 0.05 mg/Llimit 0.25 mg/L · 1 sample
Chloritebelow 0.05 mg/Llimit 0.25 mg/L · 1 sample
Free chlorine0.29 mg/Lno limit value · 10 samples
Manganesebelow 0.1 µg/Llimit 50 µg/L · 2 samples
Ironbelow 40 µg/Llimit 200 µg/L · 2 samples
Aluminium4.5 µg/Llimit 200 µg/L · 2 samples
Ammoniumbelow 0.01 mg/Llimit 0.5 mg/L · 5 samples
Chloride9.2 mg/Llimit 250 mg/L · 5 samples
Sulphate16 mg/Llimit 250 mg/L · 5 samples
Sodium2.2 mg/Llimit 200 mg/L · 2 samples
pH7.4–8.1limit 6.5–9.5 · 25 samples
Electrical conductivity543 µS/cmlimit 2,500 µS/cm · 25 samples

Non-compliant samples

What the laboratory found in the samples that were not compliant:

Samples by year

07142016: 14 samples, 7 non-compliant’162017: 14 samples, 4 non-compliant’172018: 11 samples, 1 non-compliant’182019: 11 samples, all compliant’192020: 10 samples, 1 non-compliant’202021: 10 samples, all compliant’212022: 10 samples, all compliant’222023: 10 samples, all compliant’232024: 10 samples, all compliant’242025: 10 samples, 1 non-compliant’252026: 5 samples, 2 non-compliant’26
compliant non-compliant · Drinking-water samples in Sodražica since 2016

What you can do

How to read the results

The ratings are a Draga Slovenija summary, not an official NIJZ rating.

More about water and property in Sodražica

Estimate a property’s valueProperty prices in Sodražica

Drinking water in neighbouring municipalities in Southeast Slovenia: Žužemberk, Novo mesto, Šentjernej, Straža, Šmarješke Toplice, Črnomelj, Trebnje, Mokronog - Trebelno, Šentrupert, Metlika, Semič, Dolenjske Toplice, Škocjan, Mirna, Kočevje, Kostel, Ribnica, Loški Potok, Osilnica, Mirna Peč.

Explanations of the parameters:

Follow the results for your address

When the state monitoring publishes a non-compliant result for the area by your address, we e-mail you (results come out about once a month). One address is free. This is not an urgent boil-water alert; the operator announces those.

Find your address and turn on following →

Monthly e-mail roundup: drinking water and the property market

Once a month: new drinking-water results and how the property market moved, in one e-mail. This is our existing monthly newsletter; we do not send a report for a single municipality. Unsubscribe with one click in every e-mail.

Email address only. Privacy statement.

Source: NIJZ and NLZOH, mpv.si; latest sample 31 Aug 2026. Processing: Draga Slovenija.

Frequently asked questions

Is the water in Sodražica safe to drink?

These are past results, not a verdict on the water today; the operator announces current restrictions (boil-water notices). In 2024–2026 the state monitoring took 25 samples of drinking water on the 5 supply areas serving the municipality, of which 3 were not compliant. The non-compliant samples came from smaller systems; most residents get water from systems without any. Details by water system are above.

How hard is the water in Sodražica?

By the operators’ figures and, where there are none, our estimate 12.8 °dH (averaged over the water systems, weighted by users), which is moderately hard water. To set appliances, use your own system’s figure.

Who operates the water supply in Sodražica?

Hydrovod d.o.o., Studenčevka Sušje, DOM NA TRAVNI GORI STORITVE IN TRGOVINA D. O. O.. The largest supply area is SODRAŽICA.

Where are the official drinking-water test results?

The state monitoring publishes its results at mpv.si, and the operator publishes an annual report on internal control on its website. This page summarises the state monitoring since 2016.

AI chat

Ask the data, in plain language

The AI chat finds the answer in the official register and shows it with a table you can download and a link into the map. Free; it only needs an account.

For example: Which municipalities issued the most building permits last year?

Open the AI chat

AI chat