Draga SlovenijaDraga Slovenija

Drinking water in Škocjan

Repeated or health-relevant non-compliance

In 2024–2026 the state monitoring took 25 samples of drinking water on the 4 supply areas serving the municipality, of which 3 were not compliant (E. coli or enterococci bacteria in 2 samples). By the operators’ figures and our estimate the water is hard (≈18.1 °dH).

These are state monitoring results from 2024–2026, not a notice about the water today. Current notices (boil-water, do-not-use) are published by the water-system operator on its website.

Samples 2024–2026254 supply areas
Non-compliant312%
Hardness (operator and estimate)18.1 °dHhard
Nitrate, median5.18 mg/Llimit 50 mg/L

Water systems in Škocjan

In 2024–2026 the state monitoring sampled 4 supply areas; the largest, ŠKOCJAN, supplies 2,014 users. The address search shows the nearest sampling points, not necessarily your water system; the system that supplies you is named on your water bill.

ŠKOCJAN: repeated non-complianceBUČKA: compliantRADULJE: compliantJELENDOL: compliantŠkocjanBučkaJelendolČučja MlakaDobrava pri ŠkocjanuDobruška vasDolenja Stara vasDolenje DoleDuleGabrnikŠmarješke TopliceKrškoMokronog-Trebelno5 km
  • compliant
  • repeated non-compliance

Sampling points of the state monitoring in recent years, coloured by the result for the area. Click a dot for the area's figures. Place names © OpenStreetMap

ŠKOCJAN

Repeated or health-relevant non-compliance

Operator: Komunala Novo mesto · 2,014 users · water system Škocjan 2

Samples 2024–2026
10, 3 non-compliant
Water source
Influenced by surface water
Treatment
Chlorine gas disinfection
Hardness (operator)
17.8 °dH, hard source 2022
Latest sample
29 Jun 2026
E. coli3 per 100 mLlimit 0 per 100 mL · 10 samples · 1× over the limit
Enterococci15 per 100 mLlimit 0 per 100 mL · 10 samples · 2× over the limit
Nitrate5.5 mg/Llimit 50 mg/L · 3 samples
Single pesticide (highest)0.039 µg/L (Desetil-atrazin)limit 0.1 µg/L · 2 samples
Arsenic0.16 µg/Llimit 10 µg/L · 2 samples
Manganese0.11 µg/Llimit 50 µg/L · 2 samples
Ironbelow 40 µg/Llimit 200 µg/L · 2 samples
Non-compliant samples (3)
  • · marked non-compliant; the published data gives no reason
  • · E. coli 3 per 100 mL limit 0 per 100 mL, Enterococci 15 per 100 mL limit 0 per 100 mL, Coliform bacteria 92 per 100 mL limit 0 per 100 mL
  • · Enterococci 1 per 100 mL limit 0 per 100 mL

BUČKA

All samples compliant

Operator: Komunala Novo mesto · 373 users · water system Bučka

Samples 2024–2026
5, all compliant
Water source
Influenced by surface water
Treatment
Regular disinfection, chlorine gas disinfection
Hardness (operator)
18.2 °dH, hard source 2022
Latest sample
2 Mar 2026
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples
Nitrate5.2 mg/Llimit 50 mg/L · 2 samples

RADULJE

All samples compliant

Operator: Radulje · 274 users · water system Radulje

Samples 2024–2026
5, all compliant
Water source
Influenced by surface water
Treatment
Sodium hypochlorite disinfection
Hardness (estimate)
≈19.8 °dH, hard
Latest sample
16 Apr 2026
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples
Nitrate4.1 mg/Llimit 50 mg/L · 1 sample
Lead0.48 µg/Llimit 10 µg/L · 3 samples

JELENDOL

All samples compliant

Operator: Komunala Novo mesto · 173 users · water system Jelendol

Samples 2024–2026
5, all compliant
Water source
Influenced by surface water
Treatment
Sodium hypochlorite disinfection
Hardness (operator)
18 °dH, hard source 2022
Latest sample
3 Mar 2026
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples
Nitrate3.2 mg/Llimit 50 mg/L · 1 sample

Measured values 2024–2026

The highest measured value of each parameter in the samples from the water systems that supply the municipality, and the share of the limit it reaches.

ParameterHighest valueAgainst the limit
E. coli3 per 100 mLlimit 0 per 100 mL · 25 samples · 1× over the limit
Enterococci15 per 100 mLlimit 0 per 100 mL · 25 samples · 2× over the limit
Coliform bacteria92 per 100 mLlimit 0 per 100 mL · 25 samples · 1× over the limit
Clostridium perfringens0 per 100 mLlimit 0 per 100 mL · 21 samples
Nitrate5.5 mg/Llimit 50 mg/L · 7 samples
Nitrite0.011 mg/Llimit 0.5 mg/L · 7 samples
Nitrate/50 + nitrite/30.11limit 1 · 7 samples
Single pesticide (highest)0.039 µg/L (Desetil-atrazin)limit 0.1 µg/L · 2 samples
Pesticides, total0.053 µg/Llimit 0.5 µg/L · 1 sample
Lead0.48 µg/Llimit 10 µg/L · 3 samples
Arsenic0.16 µg/Llimit 10 µg/L · 2 samples
Uranium0.3 µg/Llimit 30 µg/L · 1 sample
Copper0.0029 mg/Llimit 2 mg/L · 2 samples
Nickelbelow 0.1 µg/Llimit 20 µg/L · 1 sample
Cadmium0.021 µg/Llimit 5 µg/L · 2 samples
Chromium0.52 µg/Llimit 50 µg/L · 2 samples
Antimonybelow 0.05 µg/Llimit 10 µg/L · 2 samples
Seleniumbelow 0.1 µg/Llimit 20 µg/L · 2 samples
Boron0.0019 mg/Llimit 1.5 mg/L · 2 samples
Fluoride0.068 mg/Llimit 1.5 mg/L · 7 samples
Trihalomethanes, total2.8 µg/Llimit 100 µg/L · 2 samples
Chloratebelow 0.05 mg/Llimit 0.25 mg/L · 2 samples
Chloritebelow 0.05 mg/Llimit 0.25 mg/L · 2 samples
Free chlorine0.36 mg/Lno limit value · 15 samples
Manganese0.11 µg/Llimit 50 µg/L · 2 samples
Ironbelow 40 µg/Llimit 200 µg/L · 2 samples
Aluminium4.8 µg/Llimit 200 µg/L · 2 samples
Ammoniumbelow 0.01 mg/Llimit 0.5 mg/L · 7 samples
Chloride2.6 mg/Llimit 250 mg/L · 7 samples
Sulphate8.5 mg/Llimit 250 mg/L · 7 samples
Sodium1.2 mg/Llimit 200 mg/L · 2 samples
pH7.3–7.8limit 6.5–9.5 · 25 samples
Electrical conductivity598 µS/cmlimit 2,500 µS/cm · 25 samples

Non-compliant samples

What the laboratory found in the samples that were not compliant:

Samples by year

06112016: 11 samples, 1 non-compliant’162017: 11 samples, 1 non-compliant’172018: 11 samples, all compliant’182019: 11 samples, all compliant’192020: 10 samples, all compliant’202021: 10 samples, all compliant’212022: 10 samples, 1 non-compliant’222023: 10 samples, 1 non-compliant’232024: 10 samples, 2 non-compliant’242025: 10 samples, 1 non-compliant’252026: 5 samples, all compliant’26
compliant non-compliant · Drinking-water samples in Škocjan since 2016

What you can do

How to read the results

The ratings are a Draga Slovenija summary, not an official NIJZ rating.

More about water and property in Škocjan

Estimate a property’s valueProperty prices in Škocjan

Drinking water in neighbouring municipalities in Southeast Slovenia: Žužemberk, Novo mesto, Šentjernej, Straža, Šmarješke Toplice, Črnomelj, Trebnje, Mokronog - Trebelno, Šentrupert, Metlika, Semič, Dolenjske Toplice, Mirna, Kočevje, Sodražica, Kostel, Ribnica, Loški Potok, Osilnica, Mirna Peč.

Explanations of the parameters:

Follow the results for your address

When the state monitoring publishes a non-compliant result for the area by your address, we e-mail you (results come out about once a month). One address is free. This is not an urgent boil-water alert; the operator announces those.

Find your address and turn on following →

Monthly e-mail roundup: drinking water and the property market

Once a month: new drinking-water results and how the property market moved, in one e-mail. This is our existing monthly newsletter; we do not send a report for a single municipality. Unsubscribe with one click in every e-mail.

Email address only. Privacy statement.

Source: NIJZ and NLZOH, mpv.si; latest sample 31 Aug 2026. Processing: Draga Slovenija.

Frequently asked questions

Is the water in Škocjan safe to drink?

These are past results, not a verdict on the water today; the operator announces current restrictions (boil-water notices). In 2024–2026 the state monitoring took 25 samples of drinking water on the 4 supply areas serving the municipality, of which 3 were not compliant (E. coli or enterococci bacteria in 2 samples). Details by water system are above.

How hard is the water in Škocjan?

By the operators’ figures and, where there are none, our estimate 18.1 °dH (averaged over the water systems, weighted by users), which is hard water. To set appliances, use your own system’s figure.

Who operates the water supply in Škocjan?

Komunala Novo mesto, Radulje. The largest supply area is ŠKOCJAN.

Where are the official drinking-water test results?

The state monitoring publishes its results at mpv.si, and the operator publishes an annual report on internal control on its website. This page summarises the state monitoring since 2016.

AI chat

Ask the data, in plain language

The AI chat finds the answer in the official register and shows it with a table you can download and a link into the map. Free; it only needs an account.

For example: Which municipalities issued the most building permits last year?

Open the AI chat

AI chat