Mostly compliant

In 2024–2026 the state monitoring took 115 samples of drinking water on the 6 supply areas serving the municipality, of which 4 were not compliant (E. coli or enterococci bacteria in 1 sample). The non-compliant samples came from smaller systems; most residents get water from systems without any. By the operators’ figures and our estimate the water is moderately hard (≈10.9 °dH).

These are state monitoring results from 2024–2026, not a notice about the water today. Current notices (boil-water, do-not-use) are published by the water-system operator on its website.

Samples 2024–20261156 supply areas
Non-compliant43.5%
Hardness (operator and estimate)10.9 °dHmoderately hard
Nitrate, median4.6 mg/Llimit 50 mg/L
Hardness for settlements the operator lists separately (7)
SettlementHardnessBand
Bašelj7–8 °dHsoft
Hraše pri Preddvoru11–12 °dHmoderately hard
Hrib11–12 °dHmoderately hard
Jezersko7–8 °dHsoft
Kokra11–12 °dHmoderately hard
Potoče11–12 °dHmoderately hard
Tupaliče8–9 °dHmoderately hard

Source: Komunala Kranj, d.o.o.

Water systems in Preddvor

In 2024–2026 the state monitoring sampled 6 supply areas; the largest, KRANJ, supplies 62,489 users. The address search shows the nearest sampling points, not necessarily your water system; the system that supplies you is named on your water bill.

Supply areas at a glance
AreaUsersRating
KRANJ62,489compliant
PREDDVOR1,285occasional non-compliance
ZASELEK KOKRA CENTER45compliant
Bašelj - Laško37compliant
DOM NA ČEMŠENIKU1compliant
PLANINSKA KOČA NA SVETEM JAKOBU1Faecal bacteria in 1 sample
KRANJ: compliantPREDDVOR: occasional non-complianceMožjanca: no dataPreddvorMožjancaTupaličeZgornja BelaNova vasMačeŠenčurKamnikTržičSolčava5 km
  • compliant
  • occasional non-compliance

Sampling points of the state monitoring in recent years, coloured by the result for the area. Click a dot for the area's figures. Place names © OpenStreetMap

KRANJ

All samples compliant

Operator: Komunala Kranj · 62,489 users · water system Kranj

The area also extends into Kranj, Naklo, Šenčur.

Samples 2024–2026
95, all compliant
Water source
Influenced by surface water
Treatment
Ultrafiltration, regular disinfection, UV disinfection
Hardness (operator)
8–14 °dH, moderately hard source
Latest sample
13 Aug 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 95 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 95 samples
Nitrate6.5 mg/Llimit 50 mg/L · 10 samples
PFAS, totalbelow 0.03 µg/Llimit 0.5 µg/L · 1 sample
Arsenicbelow 1 µg/Llimit 10 µg/L · 9 samples
Manganesebelow 10 µg/Llimit 50 µg/L · 9 samples
Ironbelow 10 µg/Llimit 200 µg/L · 9 samples

PREDDVOR

Occasional non-compliance

Operator: VZ Preddvor · 1,285 users · water system Preddvor

Samples 2024–2026
10, 1 non-compliant
Water source
Groundwater, not influenced by surface water
Treatment
UV disinfection
Hardness (estimate)
≈7.6 °dH, soft
Latest sample
11 Jun 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 10 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 10 samples
Nitrate5.1 mg/Llimit 50 mg/L · 3 samples
Arsenicbelow 1 µg/Llimit 10 µg/L · 2 samples
Manganesebelow 10 µg/Llimit 50 µg/L · 2 samples
Ironbelow 10 µg/Llimit 200 µg/L · 2 samples
Non-compliant samples (1)
  • · marked non-compliant; the published data gives no reason

ZASELEK KOKRA CENTER

All samples compliant

Operator: KO KOKRA · 45 users · water system Pstotnek

Samples 2024–2026
3, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
Filters, UV disinfection
Hardness (estimate)
≈10.1 °dH, moderately hard
Latest sample
16 Apr 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 3 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 3 samples

Bašelj - Laško

All samples compliant

Operator: Komunala Kranj · 37 users · water system Bašelj - Laško

Samples 2024–2026
1, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
Regular disinfection, UV disinfection
Hardness (operator)
17–18 °dH, hard source
Latest sample
25 May 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 1 sample
Enterococci0 per 100 mLlimit 0 per 100 mL · 1 sample
Nitrate2.6 mg/Llimit 50 mg/L · 1 sample

DOM NA ČEMŠENIKU

All samples compliant

Operator: JURE SITAR · 1 user · water system Dom na Čemšeniku

Samples 2024–2026
3, all compliant
Water source
Undetermined
Hardness (estimate)
≈11.7 °dH, moderately hard
Latest sample
16 Jul 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 3 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 3 samples
Nitrate3.5 mg/Llimit 50 mg/L · 1 sample

PLANINSKA KOČA NA SVETEM JAKOBU

Faecal bacteria in 1 sample

Operator: PD PREDDVOR · 1 user · water system Planinska Koča na Svetem Jakobu

Samples 2024–2026
3, 3 non-compliant
Water source
Undetermined
Treatment
Filters, UV disinfection
Hardness (estimate)
≈4.2 °dH, soft
Latest sample
14 May 2026
Measured values
E. coli1 per 100 mLlimit 0 per 100 mL · 3 samples · 1× over the limit
Enterococci0 per 100 mLlimit 0 per 100 mL · 3 samples
Non-compliant samples (3)
  • · Coliform bacteria >80 per 100 mL limit 0 per 100 mL
  • · E. coli 1 per 100 mL limit 0 per 100 mL, Coliform bacteria 7 per 100 mL limit 0 per 100 mL
  • · marked non-compliant; the published data gives no reason

Areas with results only before 2024 (often the same water system under an older code): Možjanca.

Measured values 2024–2026

The highest measured value of each parameter in the samples from the water systems that supply the municipality, and the share of the limit it reaches.

ParameterHighest valueAgainst the limit
E. coli1 per 100 mLlimit 0 per 100 mL · 115 samples · 1× over the limit
Enterococci0 per 100 mLlimit 0 per 100 mL · 115 samples
Coliform bacteria>80 per 100 mLlimit 0 per 100 mL · 115 samples · 2× over the limit
Clostridium perfringens0 per 100 mLlimit 0 per 100 mL · 97 samples
Nitrate6.5 mg/Llimit 50 mg/L · 15 samples
Nitrite0.028 mg/Llimit 0.5 mg/L · 15 samples
Nitrate/50 + nitrite/30.13limit 1 · 15 samples
PFAS, totalbelow 0.03 µg/Llimit 0.5 µg/L · 1 sample
PFOAbelow 0.0005 µg/Lpart of the 20-PFAS sum, limit 0.1 µg/L · 1 sample
PFOSbelow 0.0005 µg/Lpart of the 20-PFAS sum, limit 0.1 µg/L · 1 sample
Arsenicbelow 1 µg/Llimit 10 µg/L · 11 samples
Uraniumbelow 10 µg/Llimit 30 µg/L · 6 samples
Copperbelow 0.01 mg/Llimit 2 mg/L · 11 samples
Nickelbelow 10 µg/Llimit 20 µg/L · 6 samples
Cadmiumbelow 1 µg/Llimit 5 µg/L · 11 samples
Chromiumbelow 10 µg/Llimit 50 µg/L · 11 samples
Antimonybelow 1 µg/Llimit 10 µg/L · 11 samples
Seleniumbelow 1 µg/Llimit 20 µg/L · 11 samples
Boronbelow 0.01 mg/Llimit 1.5 mg/L · 11 samples
Fluoridebelow 1 mg/Llimit 1.5 mg/L · 15 samples
Haloacetic acidsbelow 5 µg/Llimit 60 µg/L · 1 sample
Chloratebelow 0.002 mg/Llimit 0.25 mg/L · 1 sample
Chloritebelow 0 mg/Llimit 0.25 mg/L · 1 sample
Tetrachloroethene + trichloroethenebelow 2 µg/Llimit 10 µg/L · 4 samples
Benzenebelow 0.2 µg/Llimit 1 µg/L · 1 sample
PAHs, totalbelow 0.04 µg/Llimit 0.1 µg/L · 1 sample
Benzo(a)pyrenebelow 0.01 µg/Llimit 0.01 µg/L · 1 sample
Free chlorine0.04 mg/Lno limit value · 3 samples
Manganesebelow 10 µg/Llimit 50 µg/L · 11 samples
Ironbelow 10 µg/Llimit 200 µg/L · 11 samples
Aluminium14 µg/Llimit 200 µg/L · 11 samples
Ammoniumbelow 0.02 mg/Llimit 0.5 mg/L · 15 samples
Chloride4.5 mg/Llimit 250 mg/L · 15 samples
Sulphate7.6 mg/Llimit 250 mg/L · 15 samples
Sodium2.3 mg/Llimit 200 mg/L · 11 samples
pH7.3–8.1limit 6.5–9.5 · 115 samples
Electrical conductivity501 µS/cmlimit 2,500 µS/cm · 115 samples

Non-compliant samples

What the laboratory found in the samples that were not compliant:

Samples by year

025492016: 46 samples, 1 non-compliant’162017: 46 samples, all compliant’172018: 46 samples, 1 non-compliant’182019: 46 samples, 1 non-compliant’192020: 43 samples, all compliant’202021: 43 samples, 2 non-compliant’212022: 43 samples, 1 non-compliant’222023: 42 samples, 1 non-compliant’232024: 43 samples, all compliant’242025: 49 samples, 3 non-compliant’252026: 23 samples, 1 non-compliant’26
compliant non-compliant · Drinking-water samples in Preddvor since 2016

What you can do

How to read the results

The ratings are a Draga Slovenija summary, not an official NIJZ rating.

More about water and property in Preddvor

Estimate a property’s valueProperty prices in Preddvor

Drinking water in neighbouring municipalities in the Gorenjska region: Jesenice, Kranj, Cerklje na Gorenjskem, Tržič, Škofja Loka, Kranjska Gora, Radovljica, Bohinj, Bled, Naklo, Šenčur, Železniki, Žiri, Jezersko, Žirovnica, Gorenja vas - Poljane, Gorje.

Explanations of the parameters:

Follow the results for your address

When the state monitoring publishes a non-compliant result for the area by your address, we e-mail you (results come out about once a month). One address is free. This is not an urgent boil-water alert; the operator announces those.

Find your address and turn on following →

Monthly e-mail roundup: drinking water and the property market

Once a month: new drinking-water results and how the property market moved, in one e-mail. This is our existing monthly newsletter; we do not send a report for a single municipality. Unsubscribe with one click in every e-mail.

Email address only. Privacy statement.

Source: NIJZ and NLZOH, mpv.si; latest sample 31 Aug 2026. Processing: Draga Slovenija.

Frequently asked questions

Is the water in Preddvor safe to drink?

These are past results, not a verdict on the water today; the operator announces current restrictions (boil-water notices). In 2024–2026 the state monitoring took 115 samples of drinking water on the 6 supply areas serving the municipality, of which 4 were not compliant (E. coli or enterococci bacteria in 1 sample). The non-compliant samples came from smaller systems; most residents get water from systems without any. Details by water system are above.

How hard is the water in Preddvor?

By the operators’ figures and, where there are none, our estimate 10.9 °dH (averaged over the water systems, weighted by users), which is moderately hard water. To set appliances, use your own system’s figure.

Who operates the water supply in Preddvor?

Komunala Kranj, d.o.o., VZ Preddvor, KO KOKRA, JURE SITAR, PD PREDDVOR. The largest supply area is KRANJ.

Where are the official drinking-water test results?

The state monitoring publishes its results at mpv.si, and the operator publishes an annual report on internal control on its website. This page summarises the state monitoring since 2016.

AI chat

Ask the data, in plain language

The AI chat finds the answer in the official register and shows it with a table you can download and a link into the map. Free; it only needs an account.

For example: Which municipalities issued the most building permits last year?

Open the AI chat

AI chat