Draga SlovenijaDraga Slovenija

Drinking water in Škofja Loka

Mostly compliant

In 2024–2026 the state monitoring took 101 samples of drinking water on the 15 supply areas serving the municipality, of which 9 were not compliant (E. coli or enterococci bacteria in 5 samples). The non-compliant samples came from smaller systems; most residents get water from systems without any. The water is estimated to be moderately hard (≈8.9 °dH).

These are state monitoring results from 2024–2026, not a notice about the water today. Current notices (boil-water, do-not-use) are published by the water-system operator on its website.

Samples 2024–202610115 supply areas
Non-compliant98.9%
Hardness (estimate)8.9 °dHmoderately hard
Nitrate, median2.95 mg/Llimit 50 mg/L

Water systems in Škofja Loka

In 2024–2026 the state monitoring sampled 15 supply areas; the largest, ŠKOFJA LOKA, supplies 19,573 users. The address search shows the nearest sampling points, not necessarily your water system; the system that supplies you is named on your water bill.

Supply areas at a glance
AreaUsersRating
ŠKOFJA LOKA19,573compliant
ROVTE - LENART - LUŠA183compliant
BUKOVŠČICA120Faecal bacteria in 1 sample
DRAGA115compliant
BRODE106compliant
ŠEVLJE100occasional non-compliance
BUKOVICA93compliant
PEVNO80Faecal bacteria in 1 sample
KRIŽNA GORA74compliant
GABRK73occasional non-compliance
PRAPROTNO 2 (ŠIFRER)68compliant
ZMINEC 267Faecal bacteria in 1 sample
CRNGROB50compliant
GOSTILNA PR'BIRT40Faecal bacteria in 1 sample
TURISTIČNA KMETIJA PODMLAČAN1Faecal bacteria in 1 sample
ŠKOFJA LOKA: compliantŠKOFJA LOKA: compliantŠKOFJA LOKA: compliantŠKOFJA LOKA: compliantŠKOFJA LOKA: compliantROVTE - LENART - LUŠA: compliantBUKOVŠČICA: occasional non-complianceDRAGA: compliantBRODE: compliantŠEVLJE: occasional non-complianceBUKOVICA: compliantPEVNO: occasional non-complianceKRIŽNA GORA: compliantGABRK: occasional non-compliancePRAPROTNO 2 (ŠIFRER): compliantZMINEC 2: occasional non-complianceObršje: no dataCRNGROB: compliantŠkofja LokaPodlubnikZa BrajdoBrodeDragaBukovščicaŠevljeBukovicaKranjŽeleznikiGorenja vas-PoljaneMedvodeDobrova-Polhov GradecŠenčurLjubljanaNaklo5 km
  • compliant
  • occasional non-compliance

Sampling points of the state monitoring in recent years, coloured by the result for the area. Click a dot for the area's figures. Place names © OpenStreetMap

ŠKOFJA LOKA

All samples compliant

Operator: Komunala Škofja Loka · 19,573 users · water system Javni loški vodovod (JLV)

Samples 2024–2026
36, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
Chlorine gas disinfection, sodium hypochlorite disinfection, UV disinfection
Hardness (estimate)
≈9 °dH, moderately hard
Latest sample
25 Aug 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 36 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 36 samples
Nitrate4.4 mg/Llimit 50 mg/L · 6 samples
Leadbelow 1 µg/Llimit 10 µg/L · 1 sample
Arsenicbelow 1 µg/Llimit 10 µg/L · 4 samples
Manganesebelow 10 µg/Llimit 50 µg/L · 4 samples
Iron17 µg/Llimit 200 µg/L · 4 samples

ROVTE - LENART - LUŠA

All samples compliant

Operator: Komunala Škofja Loka · 183 users · water system Javni Vodovod Rovte - Lenart - Luša (Jvrll)

Samples 2024–2026
5, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
Regular disinfection, UV disinfection
Hardness (estimate)
≈9.8 °dH, moderately hard
Latest sample
8 Apr 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples
Nitrate5.9 mg/Llimit 50 mg/L · 2 samples

BUKOVŠČICA

Faecal bacteria in 1 sample

Operator: Strojne inštalacije, Klemen Berce s.p. · 120 users · water system Bukovščica

Samples 2024–2026
5, 1 non-compliant
Water source
Groundwater, not influenced by surface water
Treatment
No treatment
Hardness (estimate)
≈10.6 °dH, moderately hard
Latest sample
8 Apr 2026
Measured values
E. coli1 per 100 mLlimit 0 per 100 mL · 5 samples · 1× over the limit
Enterococci1 per 100 mLlimit 0 per 100 mL · 5 samples · 1× over the limit
Leadbelow 1 µg/Llimit 10 µg/L · 3 samples
Non-compliant samples (1)
  • · E. coli 1 per 100 mL limit 0 per 100 mL, Enterococci 1 per 100 mL limit 0 per 100 mL, Coliform bacteria 11 per 100 mL limit 0 per 100 mL

DRAGA

All samples compliant

Operator: VO Draga · 115 users · water system Draga

Samples 2024–2026
5, all compliant
Water source
Groundwater, not influenced by surface water
Hardness (estimate)
≈8.6 °dH, moderately hard
Latest sample
17 Mar 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples
Lead1.9 µg/Llimit 10 µg/L · 3 samples

BRODE

All samples compliant

Operator: KREK · 106 users · water system Brode

Samples 2024–2026
5, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
No treatment
Hardness (estimate)
≈1.6 °dH, soft
Latest sample
10 Apr 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples
Nitrate1.2 mg/Llimit 50 mg/L · 1 sample
Leadbelow 1 µg/Llimit 10 µg/L · 2 samples

ŠEVLJE

Occasional non-compliance

Operator: VO Ševlje · 100 users · water system Ševlje

Samples 2024–2026
5, 1 non-compliant
Water source
Groundwater, not influenced by surface water
Treatment
No treatment
Hardness (estimate)
≈9.2 °dH, moderately hard
Latest sample
8 Apr 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples
Nitrate1.5 mg/Llimit 50 mg/L · 1 sample
Leadbelow 1 µg/Llimit 10 µg/L · 3 samples
Non-compliant samples (1)
  • · Coliform bacteria 11 per 100 mL limit 0 per 100 mL

BUKOVICA

All samples compliant

Operator: Klemen Berce in Klemen Štibelj · 93 users · water system Bukovica

Samples 2024–2026
5, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
No treatment
Hardness (estimate)
≈1.2 °dH, soft
Latest sample
25 Mar 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples
Leadbelow 1 µg/Llimit 10 µg/L · 3 samples

PEVNO

Faecal bacteria in 1 sample

Operator: OBČINA ŠKOFJA LOKA · 80 users · water system Pevno

Samples 2024–2026
5, 1 non-compliant
Water source
Groundwater, not influenced by surface water
Treatment
No treatment
Hardness (estimate)
≈17.2 °dH, hard
Latest sample
17 Mar 2026
Measured values
E. coli3 per 100 mLlimit 0 per 100 mL · 5 samples · 1× over the limit
Enterococci1 per 100 mLlimit 0 per 100 mL · 5 samples · 1× over the limit
Nitrate2.8 mg/Llimit 50 mg/L · 1 sample
Leadbelow 1 µg/Llimit 10 µg/L · 3 samples
Non-compliant samples (1)
  • · E. coli 3 per 100 mL limit 0 per 100 mL, Enterococci 1 per 100 mL limit 0 per 100 mL, Coliform bacteria 7 per 100 mL limit 0 per 100 mL

KRIŽNA GORA

All samples compliant

Operator: KRIŽNA GORA · 74 users · water system Križna Gora

Samples 2024–2026
5, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
No treatment
Hardness (estimate)
≈13.5 °dH, moderately hard
Latest sample
17 Mar 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples
Nitrate4.4 mg/Llimit 50 mg/L · 2 samples
Leadbelow 1 µg/Llimit 10 µg/L · 3 samples

GABRK

Occasional non-compliance

Operator: Ogrevanje Starman · 73 users · water system Gabrk

Samples 2024–2026
5, 1 non-compliant
Water source
Groundwater, not influenced by surface water
Treatment
No treatment
Hardness (estimate)
≈1.9 °dH, soft
Latest sample
10 Apr 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples
Nitratebelow 1 mg/Llimit 50 mg/L · 1 sample
Leadbelow 1 µg/Llimit 10 µg/L · 3 samples
Non-compliant samples (1)
  • · Coliform bacteria 3 per 100 mL limit 0 per 100 mL

PRAPROTNO 2 (ŠIFRER)

All samples compliant

Operator: VZ PRAPROTNO II Z.O.O. · 68 users · water system Praprotno

Samples 2024–2026
5, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
No treatment
Hardness (estimate)
≈1 °dH, soft
Latest sample
8 Apr 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples
Leadbelow 1 µg/Llimit 10 µg/L · 2 samples

ZMINEC 2

Faecal bacteria in 1 sample

Operator: Društvo za zdravo pitno vodo Zminec II Livar · 67 users · water system Zminec 2

Samples 2024–2026
5, 1 non-compliant
Water source
Groundwater, not influenced by surface water
Treatment
No treatment
Hardness (estimate)
≈0.9 °dH, soft
Latest sample
7 May 2026
Measured values
E. coli2 per 100 mLlimit 0 per 100 mL · 5 samples · 1× over the limit
Enterococci1 per 100 mLlimit 0 per 100 mL · 5 samples · 1× over the limit
Nitrate1.2 mg/Llimit 50 mg/L · 1 sample
Leadbelow 1 µg/Llimit 10 µg/L · 2 samples
Non-compliant samples (1)
  • · E. coli 2 per 100 mL limit 0 per 100 mL, Enterococci 1 per 100 mL limit 0 per 100 mL, Coliform bacteria 2 per 100 mL limit 0 per 100 mL

CRNGROB

All samples compliant

Operator: Crngrob · 50 users · water system Crngrob

Samples 2024–2026
4, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
No treatment
Hardness (estimate)
≈12.2 °dH, moderately hard
Latest sample
17 Mar 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 4 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 4 samples

GOSTILNA PR'BIRT

Faecal bacteria in 1 sample

Operator: GOSTILNA PR'BIRT · 40 users · water system Gostilna Pr'Birt

Samples 2024–2026
3, 2 non-compliant
Water source
Groundwater, not influenced by surface water
Hardness (estimate)
≈1.2 °dH, soft
Latest sample
8 Apr 2026
Measured values
E. coli0 per 100 mLlimit 0 per 100 mL · 3 samples
Enterococci1 per 100 mLlimit 0 per 100 mL · 3 samples · 1× over the limit
Non-compliant samples (2)
  • · Coliform bacteria >80 per 100 mL limit 0 per 100 mL
  • · Enterococci 1 per 100 mL limit 0 per 100 mL, Coliform bacteria >80 per 100 mL limit 0 per 100 mL

TURISTIČNA KMETIJA PODMLAČAN

Faecal bacteria in 1 sample

Operator: TK PODMLAČAN · 1 user · water system Turistična Kmetija Podmlačan

Samples 2024–2026
3, 2 non-compliant
Water source
Groundwater, not influenced by surface water
Hardness (estimate)
≈6.5 °dH, soft
Latest sample
25 Mar 2026
Measured values
E. coli15 per 100 mLlimit 0 per 100 mL · 3 samples · 1× over the limit
Enterococci2 per 100 mLlimit 0 per 100 mL · 3 samples · 1× over the limit
Non-compliant samples (2)
  • · marked non-compliant; the published data gives no reason
  • · E. coli 15 per 100 mL limit 0 per 100 mL, Enterococci 2 per 100 mL limit 0 per 100 mL, Coliform bacteria >80 per 100 mL limit 0 per 100 mL

Areas with results only before 2024 (often the same water system under an older code): Obršje.

Measured values 2024–2026

The highest measured value of each parameter in the samples from the water systems that supply the municipality, and the share of the limit it reaches.

ParameterHighest valueAgainst the limit
E. coli15 per 100 mLlimit 0 per 100 mL · 101 samples · 4× over the limit
Enterococci2 per 100 mLlimit 0 per 100 mL · 101 samples · 5× over the limit
Coliform bacteria>80 per 100 mLlimit 0 per 100 mL · 101 samples · 8× over the limit
Clostridium perfringens0 per 100 mLlimit 0 per 100 mL · 2 samples
Nitrate5.9 mg/Llimit 50 mg/L · 15 samples
Nitritebelow 0.01 mg/Llimit 0.5 mg/L · 13 samples
Nitrate/50 + nitrite/30.12limit 1 · 14 samples
Lead1.9 µg/Llimit 10 µg/L · 28 samples
Arsenicbelow 1 µg/Llimit 10 µg/L · 4 samples
Uraniumbelow 10 µg/Llimit 30 µg/L · 2 samples
Copperbelow 0.01 mg/Llimit 2 mg/L · 4 samples
Nickelbelow 10 µg/Llimit 20 µg/L · 2 samples
Cadmiumbelow 1 µg/Llimit 5 µg/L · 4 samples
Chromiumbelow 10 µg/Llimit 50 µg/L · 4 samples
Antimonybelow 1 µg/Llimit 10 µg/L · 4 samples
Seleniumbelow 1 µg/Llimit 20 µg/L · 4 samples
Boronbelow 0.01 mg/Llimit 1.5 mg/L · 4 samples
Fluoridebelow 1 mg/Llimit 1.5 mg/L · 15 samples
Trihalomethanes, totalbelow 2 µg/Llimit 100 µg/L · 3 samples
Chloratebelow 0.002 mg/Llimit 0.25 mg/L · 2 samples
Chloritebelow 0 mg/Llimit 0.25 mg/L · 2 samples
Tetrachloroethene + trichloroethenebelow 2 µg/Llimit 10 µg/L · 4 samples
Free chlorine0.18 mg/Lno limit value · 31 samples
Manganesebelow 10 µg/Llimit 50 µg/L · 4 samples
Iron17 µg/Llimit 200 µg/L · 4 samples
Aluminium39 µg/Llimit 200 µg/L · 4 samples
Ammoniumbelow 0.02 mg/Llimit 0.5 mg/L · 15 samples
Chloride12 mg/Llimit 250 mg/L · 15 samples
Sulphate16 mg/Llimit 250 mg/L · 15 samples
Sodium6.2 mg/Llimit 200 mg/L · 4 samples
pH6.5–7.9limit 6.5–9.5 · 101 samples
Electrical conductivity512 µS/cmlimit 2,500 µS/cm · 101 samples

Non-compliant samples

What the laboratory found in the samples that were not compliant:

Samples by year

021412016: 41 samples, 8 non-compliant’162017: 41 samples, 7 non-compliant’172018: 41 samples, 5 non-compliant’182019: 41 samples, 9 non-compliant’192020: 39 samples, 12 non-compliant’202021: 39 samples, 9 non-compliant’212022: 40 samples, 10 non-compliant’222023: 39 samples, 7 non-compliant’232024: 38 samples, 3 non-compliant’242025: 41 samples, 4 non-compliant’252026: 22 samples, 2 non-compliant’26
compliant non-compliant · Drinking-water samples in Škofja Loka since 2016

What you can do

How to read the results

The ratings are a Draga Slovenija summary, not an official NIJZ rating.

More about water and property in Škofja Loka

Estimate a property’s valueProperty prices in Škofja Loka

Drinking water in neighbouring municipalities in the Gorenjska region: Jesenice, Kranj, Cerklje na Gorenjskem, Tržič, Kranjska Gora, Radovljica, Bohinj, Bled, Naklo, Šenčur, Preddvor, Železniki, Žiri, Jezersko, Žirovnica, Gorenja vas - Poljane, Gorje.

Explanations of the parameters:

Follow the results for your address

When the state monitoring publishes a non-compliant result for the area by your address, we e-mail you (results come out about once a month). One address is free. This is not an urgent boil-water alert; the operator announces those.

Find your address and turn on following →

Monthly e-mail roundup: drinking water and the property market

Once a month: new drinking-water results and how the property market moved, in one e-mail. This is our existing monthly newsletter; we do not send a report for a single municipality. Unsubscribe with one click in every e-mail.

Email address only. Privacy statement.

Source: NIJZ and NLZOH, mpv.si; latest sample 31 Aug 2026. Processing: Draga Slovenija.

Frequently asked questions

Is the water in Škofja Loka safe to drink?

These are past results, not a verdict on the water today; the operator announces current restrictions (boil-water notices). In 2024–2026 the state monitoring took 101 samples of drinking water on the 15 supply areas serving the municipality, of which 9 were not compliant (E. coli or enterococci bacteria in 5 samples). The non-compliant samples came from smaller systems; most residents get water from systems without any. Details by water system are above.

How hard is the water in Škofja Loka?

Estimated from electrical conductivity at 8.9 °dH, which is moderately hard water. The operator publishes the exact value for its network.

Who operates the water supply in Škofja Loka?

Komunala Škofja Loka d.o.o., Strojne inštalacije, Klemen Berce s.p., VO Draga, KREK, VO Ševlje. The largest supply area is ŠKOFJA LOKA.

Where are the official drinking-water test results?

The state monitoring publishes its results at mpv.si, and the operator publishes an annual report on internal control on its website. This page summarises the state monitoring since 2016.

AI chat

Ask the data, in plain language

The AI chat finds the answer in the official register and shows it with a table you can download and a link into the map. Free; it only needs an account.

For example: Which municipalities issued the most building permits last year?

Open the AI chat

AI chat