Draga SlovenijaDraga Slovenija

Drinking water: Komunala Kranj

Mostly compliant

Komunala Kranj supplies drinking water to 80,137 users in the municipalities of Kranj, Naklo, Preddvor, Šenčur, Cerklje na Gorenjskem, Jezersko. In 2024–2026 the state monitoring sampled 14 water systems of this operator and took 197 samples, of which 4 were not compliant. Water hardness differs between systems, 7.5–17.5 °dH; most customers get moderately hard water (≈10.9 °dH).

These are state monitoring results from 2024–2026, not a notice about the water today. Current notices (boil-water, do-not-use) are published by the water-system operator on its website.

Samples 2024–202619714 water systems
Non-compliant42%
Hardness7.5–17.5 °dHmoderately hard
Users80,1376 municipalities

Notices from Komunala Kranj

Boil-water notices, bans on use and supply interruptions are published by Komunala Kranj on its website (komunala-kranj.si) and in local media. This page shows state monitoring results, not current notices. What a boil-water notice means is explained on Boiling water.

Water systems run by Komunala Kranj

Water systemMunicipalitiesUsersHardness (°dH)Assessment
KranjKranj, Šenčur, Naklo, Preddvor62,48911compliant
CerkljeCerklje na Gorenjskem6,88610compliant
Kovor - NakloNaklo3,443≈11.7Occasional non-compliance
Smlednik2,253≈8.3compliant
TrstenikKranj1,34811.5compliant
GolnikKranj1,091≈10.1Occasional non-compliance
BesnicaKranj897≈15.5compliant
Jezersko - ZgornjeJezersko575≈7.8compliant
Šenturška GoraCerklje na Gorenjskem4619.5compliant
Ambrož pod KrvavcemCerklje na Gorenjskem2509.5Occasional non-compliance
JavornikKranj23615compliant
Štefanja goraCerklje na Gorenjskem1237.5compliant
PlanicaKranj4814.5Occasional non-compliance
Bašelj - LaškoPreddvor3717.5compliant

Measured values 2024–2026

ParameterHighest valueAgainst the limit
E. coli0 per 100 mLlimit 0 per 100 mL · 197 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 197 samples
Coliform bacteria12 per 100 mLlimit 0 per 100 mL · 197 samples · 4× over the limit
Clostridium perfringens0 per 100 mLlimit 0 per 100 mL · 158 samples
Nitrate15 mg/Llimit 50 mg/L · 37 samples
Nitritebelow 0.1 mg/Llimit 0.5 mg/L · 37 samples
Nitrate/50 + nitrite/30.3limit 1 · 37 samples
PFAS, totalbelow 0.03 µg/Llimit 0.5 µg/L · 3 samples
PFOAbelow 0.0005 µg/Lpart of the 20-PFAS sum, limit 0.1 µg/L · 3 samples
PFOSbelow 0.0005 µg/Lpart of the 20-PFAS sum, limit 0.1 µg/L · 3 samples
Leadbelow 1 µg/Llimit 10 µg/L · 3 samples
Arsenicbelow 1 µg/Llimit 10 µg/L · 24 samples
Uraniumbelow 10 µg/Llimit 30 µg/L · 13 samples
Copperbelow 0.01 mg/Llimit 2 mg/L · 24 samples
Nickelbelow 10 µg/Llimit 20 µg/L · 13 samples
Cadmiumbelow 1 µg/Llimit 5 µg/L · 24 samples
Chromiumbelow 10 µg/Llimit 50 µg/L · 24 samples
Antimonybelow 1 µg/Llimit 10 µg/L · 24 samples
Seleniumbelow 1 µg/Llimit 20 µg/L · 24 samples
Boronbelow 0.01 mg/Llimit 1.5 mg/L · 24 samples
Fluoridebelow 1 mg/Llimit 1.5 mg/L · 35 samples
Trihalomethanes, totalbelow 2 µg/Llimit 100 µg/L · 5 samples
Haloacetic acidsbelow 5 µg/Llimit 60 µg/L · 3 samples
Chlorate0.007 mg/Llimit 0.25 mg/L · 3 samples
Chloritebelow 0 mg/Llimit 0.25 mg/L · 3 samples
Tetrachloroethene + trichloroethenebelow 2 µg/Llimit 10 µg/L · 7 samples
Benzenebelow 0.2 µg/Llimit 1 µg/L · 1 sample
PAHs, totalbelow 0.04 µg/Llimit 0.1 µg/L · 1 sample
Benzo(a)pyrenebelow 0.01 µg/Llimit 0.01 µg/L · 1 sample
Free chlorine0.07 mg/Lno limit value · 32 samples
Manganesebelow 10 µg/Llimit 50 µg/L · 24 samples
Iron28 µg/Llimit 200 µg/L · 24 samples
Aluminium45 µg/Llimit 200 µg/L · 24 samples
Ammoniumbelow 0.02 mg/Llimit 0.5 mg/L · 37 samples
Chloride43 mg/Llimit 250 mg/L · 37 samples
Sulphate38 mg/Llimit 250 mg/L · 37 samples
Sodium2.7 mg/Llimit 200 mg/L · 24 samples
pH7.4–8.1limit 6.5–9.5 · 197 samples
Electrical conductivity520 µS/cmlimit 2,500 µS/cm · 197 samples

Non-compliant samples

Samples by year

042832016: 81 samples, 3 non-compliant’162017: 83 samples, 4 non-compliant’172018: 83 samples, 5 non-compliant’182019: 83 samples, 2 non-compliant’192020: 72 samples, 5 non-compliant’202021: 73 samples, 3 non-compliant’212022: 74 samples, 3 non-compliant’222023: 75 samples, 3 non-compliant’232024: 76 samples, 3 non-compliant’242025: 80 samples, 1 non-compliant’252026: 41 samples, all compliant’26
compliant non-compliant · Samples from Komunala Kranj systems

Municipalities

Drinking water in Kranj · Drinking water in Naklo · Drinking water in Preddvor · Drinking water in Šenčur · Drinking water in Cerklje na Gorenjskem · Drinking water in Jezersko

What you can do

How to read the results

The ratings are a Draga Slovenija summary, not an official NIJZ rating.

Source: NIJZ and NLZOH, mpv.si; latest sample 31 Aug 2026. Processing: Draga Slovenija.

Frequently asked questions

Is the water from Komunala Kranj safe to drink?

Komunala Kranj supplies drinking water to 80,137 users in the municipalities of Kranj, Naklo, Preddvor, Šenčur, Cerklje na Gorenjskem, Jezersko. In 2024–2026 the state monitoring sampled 14 water systems of this operator and took 197 samples, of which 4 were not compliant. The operator announces current restrictions on use.

How hard is the water from Komunala Kranj?

Water hardness differs between systems, 7.5–17.5 °dH; most customers get moderately hard water (≈10.9 °dH).

Where does Komunala Kranj publish boil-water notices?

On its website (https://www.komunala-kranj.si/) and in local media. A boil-water notice applies until the operator lifts it.

AI chat

Ask the data, in plain language

The AI chat finds the answer in the official register and shows it with a table you can download and a link into the map. Free; it only needs an account.

For example: Which municipalities issued the most building permits last year?

Open the AI chat

AI chat