Draga SlovenijaDraga Slovenija

Drinking water: Vodovod sistema B

Occasional non-compliance

Vodovod sistema B supplies drinking water to 51,726 users in the municipalities of Moravske Toplice, Rogašovci, Murska Sobota, Kuzma, Cankova, Tišina and 4 more. In 2024–2026 the state monitoring sampled 8 water systems of this operator and took 127 samples, of which 3 were not compliant. Water hardness differs between systems, 4.7–18.5 °dH; most customers get hard water (≈14.3 °dH).

These are state monitoring results from 2024–2026, not a notice about the water today. Current notices (boil-water, do-not-use) are published by the water-system operator on its website.

Samples 2024–20261278 water systems
Non-compliant32.4%
Hardness4.7–18.5 °dHhard
Users51,72610 municipalities

Notices from Vodovod sistema B

Boil-water notices, bans on use and supply interruptions are published by Vodovod sistema B on its website and in local media. This page shows state monitoring results, not current notices. What a boil-water notice means is explained on Boiling water.

Water systems run by Vodovod sistema B

Water systemMunicipalitiesUsersHardness (°dH)Assessment
Sistem BMurska Sobota, Moravske Toplice, Kuzma, Cankova, Rogašovci, Tišina, Ljutomer41,78114.8Occasional non-compliance
HraščiceBeltinci7,192≈12.8compliant
DomanjševciŠalovci, Moravske Toplice837≈7.3compliant
DokležovjeBeltinci795≈15.7compliant
ČepinciŠalovci425≈4.7repeated non-compliance
Rogašovci (Šola)Rogašovci300≈18.5compliant
HodošHodoš267≈8.1compliant
KramarovciRogašovci129≈18.2compliant

Measured values 2024–2026

ParameterHighest valueAgainst the limit
E. coli0 per 100 mLlimit 0 per 100 mL · 127 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 127 samples
Coliform bacteria1 per 100 mLlimit 0 per 100 mL · 127 samples · 1× over the limit
Nitrate30 mg/Llimit 50 mg/L · 21 samples
Nitritebelow 0.007 mg/Llimit 0.5 mg/L · 21 samples
Nitrate/50 + nitrite/30.6limit 1 · 21 samples
Single pesticide (highest)0.81 µg/L (Metolaklor ESA)limit 0.1 µg/L · 16 samples · 3× over the limit
Pesticides, total0.2 µg/Llimit 0.5 µg/L · 4 samples
PFAS, totalbelow 0.03 µg/Llimit 0.5 µg/L · 1 sample
PFOAbelow 0.0005 µg/Lpart of the 20-PFAS sum, limit 0.1 µg/L · 1 sample
PFOSbelow 0.0005 µg/Lpart of the 20-PFAS sum, limit 0.1 µg/L · 1 sample
Lead2.5 µg/Llimit 10 µg/L · 4 samples
Arsenicbelow 1 µg/Llimit 10 µg/L · 15 samples
Uranium2.9 µg/Llimit 30 µg/L · 9 samples
Copper0.023 mg/Llimit 2 mg/L · 15 samples
Nickelbelow 1 µg/Llimit 20 µg/L · 7 samples
Cadmium0.03 µg/Llimit 5 µg/L · 15 samples
Chromiumbelow 1 µg/Llimit 50 µg/L · 15 samples
Antimonybelow 1 µg/Llimit 10 µg/L · 15 samples
Selenium1.1 µg/Llimit 20 µg/L · 15 samples
Boron0.047 mg/Llimit 1.5 mg/L · 15 samples
Fluoride0.12 mg/Llimit 1.5 mg/L · 21 samples
Trihalomethanes, total15 µg/Llimit 100 µg/L · 12 samples
Haloacetic acidsbelow 5 µg/Llimit 60 µg/L · 1 sample
Chloratebelow 0.01 mg/Llimit 0.25 mg/L · 4 samples
Chloritebelow 0.01 mg/Llimit 0.25 mg/L · 4 samples
Tetrachloroethene + trichloroethenebelow 0.2 µg/Llimit 10 µg/L · 13 samples
Benzenebelow 0.2 µg/Llimit 1 µg/L · 1 sample
PAHs, totalbelow 0.004 µg/Llimit 0.1 µg/L · 1 sample
Benzo(a)pyrenebelow 0.004 µg/Llimit 0.01 µg/L · 1 sample
Free chlorine0.18 mg/Lno limit value · 64 samples
Manganese2.1 µg/Llimit 50 µg/L · 15 samples
Iron34 µg/Llimit 200 µg/L · 15 samples
Aluminiumbelow 10 µg/Llimit 200 µg/L · 15 samples
Ammoniumbelow 0.013 mg/Llimit 0.5 mg/L · 21 samples
Chloride29 mg/Llimit 250 mg/L · 21 samples
Sulphate46 mg/Llimit 250 mg/L · 21 samples
Sodium21 mg/Llimit 200 mg/L · 15 samples
pH6.5–7.5limit 6.5–9.5 · 127 samples
Electrical conductivity610 µS/cmlimit 2,500 µS/cm · 127 samples

Non-compliant samples

Samples by year

032642016: 55 samples, 4 non-compliant’162017: 55 samples, 1 non-compliant’172018: 63 samples, 1 non-compliant’182019: 64 samples, 3 non-compliant’192020: 44 samples, 1 non-compliant’202021: 44 samples, 1 non-compliant’212022: 44 samples, 2 non-compliant’222023: 44 samples, 1 non-compliant’232024: 46 samples, 1 non-compliant’242025: 56 samples, 2 non-compliant’252026: 25 samples, all compliant’26
compliant non-compliant · Samples from Vodovod sistema B systems

Municipalities

Drinking water in Moravske Toplice · Drinking water in Rogašovci · Drinking water in Murska Sobota · Drinking water in Kuzma · Drinking water in Cankova · Drinking water in Tišina · Drinking water in Ljutomer · Drinking water in Beltinci · Drinking water in Šalovci · Drinking water in Hodoš

What you can do

How to read the results

The ratings are a Draga Slovenija summary, not an official NIJZ rating.

Source: NIJZ and NLZOH, mpv.si; latest sample 31 Aug 2026. Processing: Draga Slovenija.

Frequently asked questions

Is the water from Vodovod sistema B safe to drink?

Vodovod sistema B supplies drinking water to 51,726 users in the municipalities of Moravske Toplice, Rogašovci, Murska Sobota, Kuzma, Cankova, Tišina and 4 more. In 2024–2026 the state monitoring sampled 8 water systems of this operator and took 127 samples, of which 3 were not compliant. The operator announces current restrictions on use.

How hard is the water from Vodovod sistema B?

Water hardness differs between systems, 4.7–18.5 °dH; most customers get hard water (≈14.3 °dH).

Where does Vodovod sistema B publish boil-water notices?

On its website and in local media. A boil-water notice applies until the operator lifts it.

AI chat

Ask the data, in plain language

The AI chat finds the answer in the official register and shows it with a table you can download and a link into the map. Free; it only needs an account.

For example: Which municipalities issued the most building permits last year?

Open the AI chat

AI chat