Drinking water: Rove - Tesen water system

Repeated or health-relevant non-compliance

The Rove - Tesen water system (operator Zagorje ob Savi) supplies 100 users in the municipality of Zagorje ob Savi. In 2024–2026 the state monitoring took 5 samples, of which 5 were not compliant.

These are state monitoring results from 2024–2026, not a notice about the water today. Current notices (boil-water, do-not-use) are published by the water-system operator on its website.

Samples 2024–202651 supply area
Non-compliant5100%
Hardness (estimate)14.5 °dHhard
Users100Zagorje ob Savi

Supply areas

ROVE - TESEN

Repeated or health-relevant non-compliance

Operator: Zagorje ob Savi · 100 users · water system Rove - Tesen

Samples 2024–2026
5, 5 non-compliant
Water source
Groundwater, not influenced by surface water
Hardness (estimate)
≈14.5 °dH, hard
Latest sample
23 Mar 2026
E. coli1 per 100 mLlimit 0 per 100 mL · 5 samples · 1× over the limit
Enterococci6 per 100 mLlimit 0 per 100 mL · 5 samples · 2× over the limit
Nitrate4 mg/Llimit 50 mg/L · 1 sample
Non-compliant samples (5)
  • · Coliform bacteria 12 per 100 mL limit 0 per 100 mL
  • · Enterococci 2 per 100 mL limit 0 per 100 mL, Coliform bacteria 73 per 100 mL limit 0 per 100 mL
  • · Coliform bacteria 1 per 100 mL limit 0 per 100 mL
  • · E. coli 1 per 100 mL limit 0 per 100 mL, Enterococci 6 per 100 mL limit 0 per 100 mL, Coliform bacteria >80 per 100 mL limit 0 per 100 mL
  • · Coliform bacteria 10 per 100 mL limit 0 per 100 mL

Measured values 2024–2026

ParameterHighest valueAgainst the limit
E. coli1 per 100 mLlimit 0 per 100 mL · 5 samples · 1× over the limit
Enterococci6 per 100 mLlimit 0 per 100 mL · 5 samples · 2× over the limit
Coliform bacteria>80 per 100 mLlimit 0 per 100 mL · 5 samples · 5× over the limit
Nitrate4 mg/Llimit 50 mg/L · 1 sample
Nitritebelow 0.007 mg/Llimit 0.5 mg/L · 1 sample
Nitrate/50 + nitrite/30.08limit 1 · 1 sample
Fluoridebelow 0.1 mg/Llimit 1.5 mg/L · 1 sample
Ammoniumbelow 0.013 mg/Llimit 0.5 mg/L · 1 sample
Chloride1.2 mg/Llimit 250 mg/L · 1 sample
Sulphate13 mg/Llimit 250 mg/L · 1 sample
pH7.6–7.8limit 6.5–9.5 · 5 samples
Electrical conductivity476 µS/cmlimit 2,500 µS/cm · 5 samples

Non-compliant samples

Samples by year

0122016: 2 samples, 1 non-compliant’162017: 2 samples, all compliant’172018: 2 samples, all compliant’182019: 2 samples, all compliant’192020: 2 samples, 1 non-compliant’202021: 2 samples, all compliant’212022: 2 samples, 1 non-compliant’222023: 2 samples, 2 non-compliant’232024: 2 samples, 2 non-compliant’242025: 2 samples, 2 non-compliant’252026: 1 sample, 1 non-compliant’26
compliant non-compliant · Samples from the Rove - Tesen water system

Municipalities

Drinking water in Zagorje ob Savi

What you can do

How to read the results

The ratings are a Draga Slovenija summary, not an official NIJZ rating.

Follow the results for your address

When the state monitoring publishes a non-compliant result for the area by your address, we e-mail you (results come out about once a month). One address is free. This is not an urgent boil-water alert; the operator announces those.

Find your address and turn on following →

Source: NIJZ and NLZOH, mpv.si; latest sample 31 Aug 2026. Processing: Draga Slovenija.

Frequently asked questions

Is the water from the Rove - Tesen water system safe to drink?

The Rove - Tesen water system (operator Zagorje ob Savi) supplies 100 users in the municipality of Zagorje ob Savi. In 2024–2026 the state monitoring took 5 samples, of which 5 were not compliant. The operator announces current restrictions on use.

How hard is the water from the Rove - Tesen water system?

Estimated from electrical conductivity at 14.5 °dH, which is hard water.