Drinking water: Vrzdenec - Žažar water system

Occasional non-compliance

The Vrzdenec - Žažar water system (operator OBČINA HORJUL) supplies 703 users in the municipality of Horjul. In 2024–2026 the state monitoring took 9 samples, of which 2 were not compliant.

These are state monitoring results from 2024–2026, not a notice about the water today. Current notices (boil-water, do-not-use) are published by the water-system operator on its website.

Samples 2024–202691 supply area
Non-compliant222%
Hardness (estimate)16.8 °dHhard
Users703OBČINA HORJUL

Supply areas

VRZDENEC - ŽAŽAR

Occasional non-compliance

Operator: OBČINA HORJUL · 703 users · water system Vrzdenec - Žažar

Samples 2024–2026
9, 2 non-compliant
Water source
Groundwater, not influenced by surface water
Treatment
Sodium hypochlorite disinfection, UV disinfection
Hardness (estimate)
≈16.8 °dH, hard
Latest sample
24 Mar 2026
E. coli0 per 100 mLlimit 0 per 100 mL · 9 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 9 samples
Nitrate2.7 mg/Llimit 50 mg/L · 2 samples
Arsenicbelow 1 µg/Llimit 10 µg/L · 2 samples
Manganesebelow 1 µg/Llimit 50 µg/L · 2 samples
Ironbelow 10 µg/Llimit 200 µg/L · 2 samples
Non-compliant samples (2)
  • · Coliform bacteria 3 per 100 mL limit 0 per 100 mL
  • · Coliform bacteria 50 per 100 mL limit 0 per 100 mL

Measured values 2024–2026

ParameterHighest valueAgainst the limit
E. coli0 per 100 mLlimit 0 per 100 mL · 9 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 9 samples
Coliform bacteria50 per 100 mLlimit 0 per 100 mL · 9 samples · 2× over the limit
Nitrate2.7 mg/Llimit 50 mg/L · 2 samples
Nitritebelow 0.007 mg/Llimit 0.5 mg/L · 2 samples
Nitrate/50 + nitrite/30.05limit 1 · 2 samples
Arsenicbelow 1 µg/Llimit 10 µg/L · 2 samples
Uranium0.51 µg/Llimit 30 µg/L · 1 sample
Copper0.0022 mg/Llimit 2 mg/L · 2 samples
Nickel2.1 µg/Llimit 20 µg/L · 1 sample
Cadmiumbelow 0.1 µg/Llimit 5 µg/L · 2 samples
Chromiumbelow 1 µg/Llimit 50 µg/L · 2 samples
Antimonybelow 1 µg/Llimit 10 µg/L · 2 samples
Selenium1.3 µg/Llimit 20 µg/L · 2 samples
Boronbelow 0.01 mg/Llimit 1.5 mg/L · 2 samples
Fluoridebelow 0.1 mg/Llimit 1.5 mg/L · 2 samples
Trihalomethanes, total1.7 µg/Llimit 100 µg/L · 2 samples
Chloratebelow 0.01 mg/Llimit 0.25 mg/L · 1 sample
Chloritebelow 0.01 mg/Llimit 0.25 mg/L · 1 sample
Free chlorine0.2 mg/Lno limit value · 7 samples
Manganesebelow 1 µg/Llimit 50 µg/L · 2 samples
Ironbelow 10 µg/Llimit 200 µg/L · 2 samples
Aluminiumbelow 10 µg/Llimit 200 µg/L · 2 samples
Ammoniumbelow 0.013 mg/Llimit 0.5 mg/L · 2 samples
Chloride24 mg/Llimit 250 mg/L · 2 samples
Sulphate13 mg/Llimit 250 mg/L · 2 samples
Sodium11 mg/Llimit 200 mg/L · 2 samples
pH7.4–7.6limit 6.5–9.5 · 9 samples
Electrical conductivity517 µS/cmlimit 2,500 µS/cm · 9 samples

Non-compliant samples

Samples by year

0352016: 5 samples, 1 non-compliant’162017: 5 samples, 3 non-compliant’172018: 5 samples, 3 non-compliant’182019: 5 samples, 1 non-compliant’192020: 4 samples, all compliant’202021: 4 samples, all compliant’212022: 4 samples, 1 non-compliant’222023: 4 samples, all compliant’232024: 4 samples, all compliant’242025: 4 samples, 2 non-compliant’252026: 1 sample, all compliant’26
compliant non-compliant · Samples from the Vrzdenec - Žažar water system

Municipalities

Drinking water in Horjul

What you can do

How to read the results

The ratings are a Draga Slovenija summary, not an official NIJZ rating.

Follow the results for your address

When the state monitoring publishes a non-compliant result for the area by your address, we e-mail you (results come out about once a month). One address is free. This is not an urgent boil-water alert; the operator announces those.

Find your address and turn on following →

Source: NIJZ and NLZOH, mpv.si; latest sample 31 Aug 2026. Processing: Draga Slovenija.

Frequently asked questions

Is the water from the Vrzdenec - Žažar water system safe to drink?

The Vrzdenec - Žažar water system (operator OBČINA HORJUL) supplies 703 users in the municipality of Horjul. In 2024–2026 the state monitoring took 9 samples, of which 2 were not compliant. The operator announces current restrictions on use.

How hard is the water from the Vrzdenec - Žažar water system?

Estimated from electrical conductivity at 16.8 °dH, which is hard water.