Mostly compliant

In 2024–2026 the state monitoring took 29 samples of drinking water on the 4 supply areas serving the municipality, of which 4 were not compliant. The non-compliant samples came from smaller systems; most residents get water from systems without any. The water is estimated to be moderately hard (≈13.8 °dH).

These are state monitoring results from 2024–2026, not a notice about the water today. Current notices (boil-water, do-not-use) are published by the water-system operator on its website.

Samples 2024–2026294 supply areas
Non-compliant414%
Hardness (estimate)13.8 °dHmoderately hard
Nitrate, median31 mg/Llimit 50 mg/L

Water systems in Radenci

In 2024–2026 the state monitoring sampled 4 supply areas; the largest, Vodarna Podgrad - Segovci - omrežje G. RADGONA in Radenci, supplies 13,600 users. The address search shows the nearest sampling points, not necessarily your water system; the system that supplies you is named on your water bill.

Vodarna Podgrad - Segovci - omrežje G. RADGONA in Radenci: compliantVODARNA PODGRAD - SEGOVCI (OMREŽJE RADENCI): compliantHRASTJE MOTA: repeated non-complianceHRAŠENSKI VRH (VAŠKI): compliantRadenciSpodnji KocjanBoračevaHrastje-MotaJanžev VrhOkoslavciParičjakKapelski VrhŠratovciSveti Jurij ob ŠčavniciTišinaMurska SobotaKriževci2 km
  • compliant
  • repeated non-compliance

Sampling points of the state monitoring in recent years, coloured by the result for the area. Click a dot for the area's figures. Place names © OpenStreetMap

Vodarna Podgrad - Segovci - omrežje G. RADGONA in Radenci

All samples compliant

Operator: Prleška komunala · 13,600 users · water system sistema C - Prlekija

The area also extends into Gornja Radgona.

Samples 2024–2026
10, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
Sodium hypochlorite disinfection
Hardness (estimate)
≈14.5 °dH, hard
Latest sample
3 Jul 2024
E. coli0 per 100 mLlimit 0 per 100 mL · 10 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 10 samples
Nitrate27 mg/Llimit 50 mg/L · 2 samples
Arsenicbelow 1 µg/Llimit 10 µg/L · 2 samples
Manganesebelow 1 µg/Llimit 50 µg/L · 2 samples
Ironbelow 10 µg/Llimit 200 µg/L · 2 samples

VODARNA PODGRAD - SEGOVCI (OMREŽJE RADENCI)

All samples compliant

Operator: Komunala Radgona · 5,600 users · water system Sistem C

The area also extends into Gornja Radgona.

Samples 2024–2026
9, all compliant
Water source
Groundwater, not influenced by surface water
Hardness (operator)
12.3 °dH, moderately hard source
Latest sample
17 Jun 2026
E. coli0 per 100 mLlimit 0 per 100 mL · 9 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 9 samples
Nitrate35 mg/Llimit 50 mg/L · 3 samples
Single pesticide (highest)0.052 µg/L (Metolaklor ESA)limit 0.1 µg/L · 2 samples
PFAS, totalbelow 0.03 µg/Llimit 0.5 µg/L · 1 sample
Arsenicbelow 1 µg/Llimit 10 µg/L · 3 samples
Manganese1.3 µg/Llimit 50 µg/L · 3 samples
Ironbelow 10 µg/Llimit 200 µg/L · 3 samples

HRASTJE MOTA

Repeated or health-relevant non-compliance

Operator: Komunala Radgona · 254 users · water system Hrastje Mota

Samples 2024–2026
5, 4 non-compliant
Water source
Groundwater, not influenced by surface water
Treatment
Sodium hypochlorite disinfection
Hardness (operator)
11.2 °dH, moderately hard source
Latest sample
6 May 2026
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples
Single pesticide (highest)1.6 µg/L (Metolaklor ESA)limit 0.1 µg/L · 3 samples · 3× over the limit
Lead0.2 µg/Llimit 10 µg/L · 2 samples
Non-compliant samples (4)
  • · Single pesticide (highest) (Metolaklor ESA) 0.29 µg/L limit 0.1 µg/L
  • · Coliform bacteria 13 per 100 mL limit 0 per 100 mL, Single pesticide (highest) (Metolaklor ESA) 0.44 µg/L limit 0.1 µg/L
  • · Single pesticide (highest) (Metolaklor ESA) 1.6 µg/L limit 0.1 µg/L
  • · marked non-compliant; the published data gives no reason

HRAŠENSKI VRH (VAŠKI)

All samples compliant

Operator: Komunala Radgona · 130 users · water system Hrašenski Vrh (Vaški)

Samples 2024–2026
5, all compliant
Water source
Groundwater, not influenced by surface water
Treatment
Sodium hypochlorite disinfection
Hardness (operator)
11.8 °dH, moderately hard source
Latest sample
27 May 2026
E. coli0 per 100 mLlimit 0 per 100 mL · 5 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 5 samples
Single pesticide (highest)below 0.05 µg/Llimit 0.1 µg/L · 1 sample
Lead0.84 µg/Llimit 10 µg/L · 3 samples

Measured values 2024–2026

The highest measured value of each parameter in the samples from the water systems that supply the municipality, and the share of the limit it reaches.

ParameterHighest valueAgainst the limit
E. coli0 per 100 mLlimit 0 per 100 mL · 29 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 29 samples
Coliform bacteria13 per 100 mLlimit 0 per 100 mL · 29 samples · 1× over the limit
Clostridium perfringens0 per 100 mLlimit 0 per 100 mL · 1 sample
Nitrate35 mg/Llimit 50 mg/L · 5 samples
Nitritebelow 0.007 mg/Llimit 0.5 mg/L · 5 samples
Nitrate/50 + nitrite/30.7limit 1 · 5 samples
Single pesticide (highest)1.6 µg/L (Metolaklor ESA)limit 0.1 µg/L · 6 samples · 3× over the limit
Pesticides, total0.31 µg/Llimit 0.5 µg/L · 2 samples
PFAS, totalbelow 0.03 µg/Llimit 0.5 µg/L · 1 sample
PFOAbelow 0.0005 µg/Lpart of the 20-PFAS sum, limit 0.1 µg/L · 1 sample
PFOSbelow 0.0005 µg/Lpart of the 20-PFAS sum, limit 0.1 µg/L · 1 sample
Lead0.84 µg/Llimit 10 µg/L · 5 samples
Arsenicbelow 1 µg/Llimit 10 µg/L · 5 samples
Uranium0.55 µg/Llimit 30 µg/L · 3 samples
Copper0.0079 mg/Llimit 2 mg/L · 5 samples
Nickelbelow 1 µg/Llimit 20 µg/L · 3 samples
Cadmium0.021 µg/Llimit 5 µg/L · 5 samples
Chromiumbelow 1 µg/Llimit 50 µg/L · 5 samples
Antimonybelow 1 µg/Llimit 10 µg/L · 5 samples
Seleniumbelow 1 µg/Llimit 20 µg/L · 5 samples
Boron0.03 mg/Llimit 1.5 mg/L · 5 samples
Fluoridebelow 0.1 mg/Llimit 1.5 mg/L · 5 samples
Trihalomethanes, total5.3 µg/Llimit 100 µg/L · 4 samples
Haloacetic acidsbelow 5 µg/Llimit 60 µg/L · 1 sample
Chlorate0.24 mg/Llimit 0.25 mg/L · 4 samples
Chloritebelow 0.01 mg/Llimit 0.25 mg/L · 4 samples
Tetrachloroethene + trichloroethenebelow 0.2 µg/Llimit 10 µg/L · 3 samples
Free chlorine0.16 mg/Lno limit value · 23 samples
Manganese1.3 µg/Llimit 50 µg/L · 5 samples
Ironbelow 10 µg/Llimit 200 µg/L · 5 samples
Aluminiumbelow 10 µg/Llimit 200 µg/L · 5 samples
Ammoniumbelow 0.013 mg/Llimit 0.5 mg/L · 5 samples
Chloride26 mg/Llimit 250 mg/L · 5 samples
Sulphate23 mg/Llimit 250 mg/L · 5 samples
Sodium12 mg/Llimit 200 mg/L · 5 samples
pH6.8–7.3limit 6.5–9.5 · 29 samples
Electrical conductivity590 µS/cmlimit 2,500 µS/cm · 29 samples

Non-compliant samples

What the laboratory found in the samples that were not compliant:

Samples by year

08162016: 13 samples, 4 non-compliant’162017: 13 samples, 1 non-compliant’172018: 15 samples, 3 non-compliant’182019: 16 samples, all compliant’192020: 14 samples, all compliant’202021: 14 samples, 2 non-compliant’212022: 14 samples, 1 non-compliant’222023: 14 samples, all compliant’232024: 14 samples, 1 non-compliant’242025: 10 samples, 2 non-compliant’252026: 5 samples, 1 non-compliant’26
compliant non-compliant · Drinking-water samples in Radenci since 2016

What you can do

How to read the results

The ratings are a Draga Slovenija summary, not an official NIJZ rating.

More about water and property in Radenci

Estimate a property’s valueProperty prices in Radenci

Drinking water in neighbouring municipalities in the Pomurska region: Gornja Radgona, Apače, Murska Sobota, Moravske Toplice, Ljutomer, Kuzma, Rogašovci, Cankova, Tišina, Križevci, Lendava, Turnišče, Odranci, Črenšovci, Beltinci, Velika Polana, Hodoš, Gornji Petrovci, Puconci, Šalovci.

Explanations of the parameters:

Follow the results for your address

When the state monitoring publishes a non-compliant result for the area by your address, we e-mail you (results come out about once a month). One address is free. This is not an urgent boil-water alert; the operator announces those.

Find your address and turn on following →

Monthly e-mail roundup: drinking water and the property market

Once a month: new drinking-water results and how the property market moved, in one e-mail. This is our existing monthly newsletter; we do not send a report for a single municipality. Unsubscribe with one click in every e-mail.

Email address only. Privacy statement.

Source: NIJZ and NLZOH, mpv.si; latest sample 31 Aug 2026. Processing: Draga Slovenija.

Frequently asked questions

Is the water in Radenci safe to drink?

These are past results, not a verdict on the water today; the operator announces current restrictions (boil-water notices). In 2024–2026 the state monitoring took 29 samples of drinking water on the 4 supply areas serving the municipality, of which 4 were not compliant. The non-compliant samples came from smaller systems; most residents get water from systems without any. Details by water system are above.

How hard is the water in Radenci?

Estimated from electrical conductivity at 13.8 °dH, which is moderately hard water. The operator publishes the exact value for its network.

Who operates the water supply in Radenci?

PRLEŠKA KOMUNALA D.O.O., Komunala Radgona d.o.o.. The largest supply area is Vodarna Podgrad - Segovci - omrežje G. RADGONA in Radenci.

Where are the official drinking-water test results?

The state monitoring publishes its results at mpv.si, and the operator publishes an annual report on internal control on its website. This page summarises the state monitoring since 2016.

AI chat

Ask the data, in plain language

The AI chat finds the answer in the official register and shows it with a table you can download and a link into the map. Free; it only needs an account.

For example: Which municipalities issued the most building permits last year?

Open the AI chat

AI chat