Draga SlovenijaDraga Slovenija

Drinking water: VIK Nova Gorica

Occasional non-compliance

VIK Nova Gorica (Vodovodi in kanalizacija Nova Gorica d.d.) supplies drinking water to 49,247 users in the municipalities of Nova Gorica, Miren - Kostanjevica, Renče - Vogrsko, Brda. In 2024–2026 the state monitoring sampled 11 water systems of this operator and took 154 samples, of which 5 were not compliant. Water hardness differs between systems, 7.3–13.9 °dH; most customers get soft water (≈7.6 °dH).

These are state monitoring results from 2024–2026, not a notice about the water today. Current notices (boil-water, do-not-use) are published by the water-system operator on its website.

Samples 2024–202615411 water systems
Non-compliant53.2%
Hardness7.3–13.9 °dHsoft
Users49,2474 municipalities

Notices from VIK Nova Gorica

Boil-water notices, bans on use and supply interruptions are published by VIK Nova Gorica on its website (vik-ng.si) and in local media. This page shows state monitoring results, not current notices. What a boil-water notice means is explained on Boiling water.

Water systems run by VIK Nova Gorica

Water systemMunicipalitiesUsersHardness (°dH)Assessment
MrzlekBrda, Nova Gorica, Miren - Kostanjevica35,2237.5Occasional non-compliance
Hubelj NGRenče - Vogrsko, Nova Gorica8,2957.3Occasional non-compliance
Osek - VitovljeNova Gorica2,0537.3compliant
KromberkNova Gorica8997.7compliant
Čepovan - TrnovoNova Gorica85010.7compliant
GrgarNova Gorica78211.1compliant
OzeljanNova Gorica6017.8compliant
Bate - BanjšiceNova Gorica41311.6compliant
Dol pri ČepovanuNova Gorica69≈12.5compliant
GOLO BRDO (zajetje v Italiji)Brda54≈13.9compliant
Lokatonci Sveta GoraNova Gorica8≈13.1Occasional non-compliance

Measured values 2024–2026

ParameterHighest valueAgainst the limit
E. coli0 per 100 mLlimit 0 per 100 mL · 154 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 154 samples
Coliform bacteria80 per 100 mLlimit 0 per 100 mL · 154 samples · 4× over the limit
Clostridium perfringens0 per 100 mLlimit 0 per 100 mL · 123 samples
Nitrate7.1 mg/Llimit 50 mg/L · 33 samples
Nitritebelow 0.013 mg/Llimit 0.5 mg/L · 33 samples
Nitrate/50 + nitrite/30.14limit 1 · 33 samples
PFAS, totalbelow 0.03 µg/Llimit 0.5 µg/L · 3 samples
PFOAbelow 0.0005 µg/Lpart of the 20-PFAS sum, limit 0.1 µg/L · 3 samples
PFOSbelow 0.0005 µg/Lpart of the 20-PFAS sum, limit 0.1 µg/L · 3 samples
Arsenic0.1 µg/Llimit 10 µg/L · 27 samples
Uranium0.24 µg/Llimit 30 µg/L · 15 samples
Copper0.014 mg/Llimit 2 mg/L · 27 samples
Nickel3.3 µg/Llimit 20 µg/L · 15 samples
Cadmium0.032 µg/Llimit 5 µg/L · 27 samples
Chromium3.6 µg/Llimit 50 µg/L · 27 samples
Mercury0.012 µg/Llimit 1 µg/L · 13 samples
Antimony0.34 µg/Llimit 10 µg/L · 27 samples
Selenium0.14 µg/Llimit 20 µg/L · 27 samples
Boron0.0057 mg/Llimit 1.5 mg/L · 27 samples
Fluoridebelow 1 mg/Llimit 1.5 mg/L · 33 samples
Trihalomethanes, total9.8 µg/Llimit 100 µg/L · 24 samples
Haloacetic acidsbelow 5 µg/Llimit 60 µg/L · 3 samples
Bromatebelow 3 µg/Llimit 10 µg/L · 24 samples
Chloratebelow 0.05 mg/Llimit 0.25 mg/L · 5 samples
Chloritebelow 0.05 mg/Llimit 0.25 mg/L · 5 samples
Free chlorine0.23 mg/Lno limit value · 91 samples
Manganese3 µg/Llimit 50 µg/L · 27 samples
Iron55 µg/Llimit 200 µg/L · 27 samples
Aluminium76 µg/Llimit 200 µg/L · 62 samples
Ammonium0.064 mg/Llimit 0.5 mg/L · 33 samples
Chloride7.5 mg/Llimit 250 mg/L · 33 samples
Sulphate80 mg/Llimit 250 mg/L · 33 samples
Sodium2.2 mg/Llimit 200 mg/L · 27 samples
pH7.6–8.3limit 6.5–9.5 · 154 samples
Electrical conductivity466 µS/cmlimit 2,500 µS/cm · 154 samples

Non-compliant samples

Samples by year

037732016: 67 samples, 1 non-compliant’162017: 67 samples, 1 non-compliant’172018: 67 samples, 2 non-compliant’182019: 73 samples, 3 non-compliant’192020: 61 samples, 1 non-compliant’202021: 61 samples, all compliant’212022: 61 samples, 2 non-compliant’222023: 53 samples, 2 non-compliant’232024: 61 samples, 3 non-compliant’242025: 61 samples, 2 non-compliant’252026: 32 samples, all compliant’26
compliant non-compliant · Samples from VIK Nova Gorica systems

Municipalities

Drinking water in Nova Gorica · Drinking water in Miren - Kostanjevica · Drinking water in Renče - Vogrsko · Drinking water in Brda

What you can do

How to read the results

The ratings are a Draga Slovenija summary, not an official NIJZ rating.

Source: NIJZ and NLZOH, mpv.si; latest sample 31 Aug 2026. Processing: Draga Slovenija.

Frequently asked questions

Is the water from VIK Nova Gorica safe to drink?

VIK Nova Gorica (Vodovodi in kanalizacija Nova Gorica d.d.) supplies drinking water to 49,247 users in the municipalities of Nova Gorica, Miren - Kostanjevica, Renče - Vogrsko, Brda. In 2024–2026 the state monitoring sampled 11 water systems of this operator and took 154 samples, of which 5 were not compliant. The operator announces current restrictions on use.

How hard is the water from VIK Nova Gorica?

Water hardness differs between systems, 7.3–13.9 °dH; most customers get soft water (≈7.6 °dH).

Where does VIK Nova Gorica publish boil-water notices?

On its website (https://vik-ng.si/) and in local media. A boil-water notice applies until the operator lifts it.

AI chat

Ask the data, in plain language

The AI chat finds the answer in the official register and shows it with a table you can download and a link into the map. Free; it only needs an account.

For example: Which municipalities issued the most building permits last year?

Open the AI chat

AI chat