Occasional non-compliance

JKP Žalec supplies drinking water to 38,701 users in the municipalities of Žalec, Braslovče, Polzela, Prebold, Velenje, Vransko and 1 more. In 2024–2026 the state monitoring sampled 13 water systems of this operator and took 126 samples, of which 3 were not compliant. Water hardness differs between systems, 4–18.9 °dH; most customers get moderately hard water (≈10.9 °dH).

These are state monitoring results from 2024–2026, not a notice about the water today. Current notices (boil-water, do-not-use) are published by the water-system operator on its website.

Samples 2024–202612613 water systems
Non-compliant32.4%
Hardness4–18.9 °dHmoderately hard
Users38,7017 municipalities

Notices from JKP Žalec

Boil-water notices, bans on use and supply interruptions are published by JKP Žalec on its website (jkp-zalec.si) and in local media. This page shows state monitoring results, not current notices. What a boil-water notice means is explained on Boiling water.

Water systems run by JKP Žalec

Water systemMunicipalitiesUsersHardness (°dH)Assessment
ŽalecŽalec13,1309.6Occasional non-compliance
Vransko - PolzelaBraslovče, Polzela9,63712.9compliant
ŠempeterŽalec4,35610.7compliant
TaborBraslovče4,0869.6compliant
PreboldPrebold2,53110.7compliant
GrižeŽalec2,26611.6compliant
LetušBraslovče1,00911.1compliant
Podvin - DobričPolzela72114.2Occasional non-compliance
PonikvaŽalec3857.6compliant
PodkrajVelenje21118.9compliant
Zabukovica VasŽalec200≈9.1compliant
TešovaVransko1039.2Occasional non-compliance
SmrekovinaTrbovlje66≈4compliant

Measured values 2024–2026

ParameterHighest valueAgainst the limit
E. coli0 per 100 mLlimit 0 per 100 mL · 126 samples
Enterococci0 per 100 mLlimit 0 per 100 mL · 126 samples
Coliform bacteria0 per 100 mLlimit 0 per 100 mL · 126 samples
Clostridium perfringens0 per 100 mLlimit 0 per 100 mL · 24 samples
Nitrate36 mg/Llimit 50 mg/L · 27 samples
Nitrite0.007 mg/Llimit 0.5 mg/L · 27 samples
Nitrate/50 + nitrite/30.72limit 1 · 27 samples
Single pesticide (highest)0.025 µg/L (Desetil-atrazin)limit 0.1 µg/L · 10 samples
Pesticides, totalbelow 0.05 µg/Llimit 0.5 µg/L · 2 samples
PFAS, totalbelow 0.03 µg/Llimit 0.5 µg/L · 2 samples
PFOAbelow 0.0005 µg/Lpart of the 20-PFAS sum, limit 0.1 µg/L · 2 samples
PFOSbelow 0.0005 µg/Lpart of the 20-PFAS sum, limit 0.1 µg/L · 2 samples
Lead0.17 µg/Llimit 10 µg/L · 3 samples
Arsenicbelow 1 µg/Llimit 10 µg/L · 20 samples
Uranium1.3 µg/Llimit 30 µg/L · 11 samples
Copper0.0066 mg/Llimit 2 mg/L · 20 samples
Nickelbelow 1 µg/Llimit 20 µg/L · 11 samples
Cadmiumbelow 0.1 µg/Llimit 5 µg/L · 20 samples
Chromiumbelow 1 µg/Llimit 50 µg/L · 20 samples
Antimonybelow 1 µg/Llimit 10 µg/L · 20 samples
Selenium2 µg/Llimit 20 µg/L · 20 samples
Boron0.018 mg/Llimit 1.5 mg/L · 20 samples
Fluoridebelow 0.1 mg/Llimit 1.5 mg/L · 27 samples
Trihalomethanes, total3.4 µg/Llimit 100 µg/L · 17 samples
Haloacetic acids11 µg/Llimit 60 µg/L · 2 samples
Chloratebelow 0.05 mg/Llimit 0.25 mg/L · 1 sample
Chloritebelow 0.05 mg/Llimit 0.25 mg/L · 1 sample
Tetrachloroethene + trichloroethenebelow 0.2 µg/Llimit 10 µg/L · 1 sample
Free chlorine0.45 mg/Lno limit value · 70 samples
Manganesebelow 1 µg/Llimit 50 µg/L · 20 samples
Iron11 µg/Llimit 200 µg/L · 20 samples
Aluminiumbelow 10 µg/Llimit 200 µg/L · 20 samples
Ammoniumbelow 0.05 mg/Llimit 0.5 mg/L · 27 samples
Chloride15 mg/Llimit 250 mg/L · 27 samples
Sulphate20 mg/Llimit 250 mg/L · 27 samples
Sodium6.2 mg/Llimit 200 mg/L · 20 samples
pH6.5–8.1limit 6.5–9.5 · 126 samples
Electrical conductivity633 µS/cmlimit 2,500 µS/cm · 126 samples

Non-compliant samples

Samples by year

030592016: 58 samples, 2 non-compliant’162017: 59 samples, 2 non-compliant’172018: 59 samples, all compliant’182019: 59 samples, 3 non-compliant’192020: 50 samples, 1 non-compliant’202021: 50 samples, 3 non-compliant’212022: 49 samples, 2 non-compliant’222023: 50 samples, 2 non-compliant’232024: 50 samples, 1 non-compliant’242025: 50 samples, 1 non-compliant’252026: 26 samples, 1 non-compliant’26
compliant non-compliant · Samples from JKP Žalec systems

Municipalities

Drinking water in Žalec · Drinking water in Braslovče · Drinking water in Polzela · Drinking water in Prebold · Drinking water in Velenje · Drinking water in Vransko · Drinking water in Trbovlje

What you can do

How to read the results

The ratings are a Draga Slovenija summary, not an official NIJZ rating.

Source: NIJZ and NLZOH, mpv.si; latest sample 31 Aug 2026. Processing: Draga Slovenija.

Frequently asked questions

Is the water from JKP Žalec safe to drink?

JKP Žalec supplies drinking water to 38,701 users in the municipalities of Žalec, Braslovče, Polzela, Prebold, Velenje, Vransko and 1 more. In 2024–2026 the state monitoring sampled 13 water systems of this operator and took 126 samples, of which 3 were not compliant. The operator announces current restrictions on use.

How hard is the water from JKP Žalec?

Water hardness differs between systems, 4–18.9 °dH; most customers get moderately hard water (≈10.9 °dH).

Where does JKP Žalec publish boil-water notices?